Gas boilers today are widely used for heating objects for various purposes. These can be industrial premises, offices and residential buildings. Such devices are economical when used in heating and hot water supply systems.

Among their advantages, environmental friendliness should also be highlighted, which is achieved by using components that reduce the release of harmful substances into the external environment. If you also decide to purchase one of these devices, you should consider several models. But first, it is important to decide on the manufacturer.

Thermona boilers are one of the most popular today. They are offered for sale in several varieties, among them the following should be highlighted:

  • condensation;
  • wall;
  • floor

The former provide an opportunity to save effectively. The latter have relatively little power, while the third are located on the floor and often provide heating and hot water supply. They have cast iron heat exchangers and are modern equipment used in industrial premises, private homes and social infrastructure facilities.

New models have made it possible to achieve maximum heat transfer with minimal emissions of harmful substances. This indicates the possibility of economical operation that does not harm the environment. Such devices have adjustable performance, which allows high-precision adjustment of the indoor temperature, which will depend on heat loss. The equipment is of high quality and uses components manufactured by the world's leading manufacturers.

Reviews of condensing boiler 14 KD.A

This wall mounted Thermona boiler has a heating output ranging from 2.4 to 14.6 kW. It does not provide hot water heating. The device is a modern water heating unit running on liquefied natural gas.

According to consumers, the equipment operates economically and is distinguished by the fact that it does not cause damage to the external environment. Buyers quite often choose this wall-mounted Thermona boiler for another reason that it allows you to adjust the power in the range from 16 to 100%. Adaptation to the heat loss of the object is carried out automatically.

The boiler can be used to heat hot water, but using an external tank. According to buyers, the Thermona gas boiler is excellent for those homes where energy is consumed in a small amount. You can install this equipment in combination with floor heating. The device is equipped with an energy-efficient circulation pump, which reduces energy consumption by up to 50% compared to similar pumps.

Reviews about the technical characteristics of the model

The Thermona gas boiler described above, according to consumers, is very easy to use. Natural gas consumption is low and can reach 1.46 m 3 /h. The maximum heating outlet temperature reaches 80 °C.

The expansion tank holds 6 liters. The boiler efficiency is declared by the manufacturer at 108%. The degree of protection of electrical components corresponds to IP 41 (D). The equipment weighs only 32 kg. Its height, width and depth are 725x430x300 mm.

Reviews of wall-mounted boiler 14 CLN, TCLN

This wall-mounted unit has a thermal output ranging from 5.5 to 14 kW. The device provides heating of hot water. This double-circuit equipment is used for heating and hot water supply of various objects. Consumers like that water is prepared in a thermal heat exchanger using a flow-through method.

Automation provides priority for water heating. You can smoothly adjust the power from 45 to 100%. When buyers consider the described Thermona boiler, they often pay attention to the safety group, which provides for built-in protection of the circulation pump from blocking, protection of the boiler from freezing and overheating. In the new design, the devices provide the operator with the ability to adjust the temperature taking into account external conditions.

Reviews of the floor-standing boiler brand 18 EZ/B

To get a more complete picture, it is also necessary to consider the Thermona floor-standing boiler, the model of which was mentioned above. The thermal power of this equipment is adjustable from 10 to 18 kW. The device is dual-circuit and provides the ability to heat hot water. The unit is volatile, that is, it works with a connection to the electrical network. Sometimes consumers refuse this model for the reason mentioned.

But this boiler option has many advantages. For example, the device is equipped with an electronic unit that is configured to modulate the operation of the burner. Equipment belonging to the EZ/B model range uses an automatic system that switches the three-way valve when the water temperature drops to 60 °C and directs the flow from the heating circuit to the boiler circuit. This Thermona floor-standing boiler has a cast iron heat exchanger, which has a new section design. This indicates the efficient use of gas combustion energy.

Instructions

Before you start operating, you must read the instructions for the Thermona gas boiler. After reading it, you will be able to understand that it is extremely important to follow safety rules. They state that if there is a smell of gas while the equipment is operating, it is necessary to turn off the fuel supply valve under the boiler and ensure intensive ventilation of the room. To do this, open all doors and windows.

Electrical switches should not be manipulated when creating the situation described above. It is extremely important to extinguish any open fire before calling a service technician.

Security measures

The instructions for the Thermona boiler also say that if there is a smell of flue gases, the boiler must be turned off and a flow of fresh air into the room must be ensured. Then you need to invite a service specialist.

When a fire occurs in an appliance, you need to turn off the gas supply valve and disconnect the equipment from the electrical network. The fire is extinguished with a carbon dioxide or powder fire extinguisher.

Finally

Thermona boilers are offered for sale in several lines, which are represented by condensing, floor-mounted and wall-mounted options. If you do not need hot water in your home, then you should not overpay by purchasing dual-circuit equipment. In this case, a single-circuit Thermona boiler is usually suitable. It will have smooth power control, which will save fuel.

But if you need to equip a powerful heating system and provide your household with hot water, then you will not be able to do without a powerful floor-standing model of a gas boiler. True, you should be prepared to spend more than when buying a single-circuit model, which will take up much less space.

External fault signaling module of the MS2 series of boilers and cascade boiler houses THERMONA. Installation and operation instructions. Language: RU | pdf 970.17 Kb

Programmable controller TRONIC 2008 E series. Installation and operating instructions. Language: RU | pdf 970.90 Kb

Installation of a fault signaling system for the MS1 series of boilers and cascade boiler houses THERMONA. Installation and operation instructions. Language: RU | pdf 379.68 Kb

Digital room regulators PT 10 series for automatic heating control. Installation and operation instructions. Language: RU | pdf 181.85 Kb

Digital room regulators PT 21 series for automatic heating control. Installation and operation instructions. Language: EN | pdf 193.57 Kb

Digital regulators of the PT 55, PT 55 Lite series for automatic heating control. Installation and operation instructions. Language: RU | pdf 1.02 Mb

Digital room regulators PT 55 X series for automatic heating control. Installation and operation instructions. Language: RU | pdf 1.23 Mb

GST1 - GSM module for connection to the PT 55 X thermostat and control via a mobile phone. Installation and operation instructions. Language: RU | pdf 145.97 Kb

Digital room regulators PT 59 X series for automatic heating control. Installation and operation instructions. Language: RU | pdf 430.54 Kb

    • Cast iron floor-standing gas boilers of the 18 P/B, 25 P/B, 35 P/B, 45 P/B series without power supply for heating. Installation and operation instructions. Language: RU | pdf 910.58 Kb

      Floor-standing gas boilers of the 60 E, 80 E, 100 E, 120 E series with power supply for heating. Installation and operation instructions. Language: RU | pdf 1.09 Mb

      Wall-mounted floor-standing boilers of the Therm 18 E/B, EZB series; Therm 25 E/B, EZB, Therm 35 E/B, EZB; Therm 45 E/B, EZB; Therm 55 E/B, EZB; Service manual for installation and service organizations Language: RU | pdf 906.22 Kb

    • Wall-mounted gas boilers of the PRO 14 L, 14 TL series are for heating only. Installation and operation instructions. Language: RU | pdf 1.03 Mb

      Gas wall-mounted boilers of the DUO 50FT series with a closed combustion chamber. Installation and operation instructions. Language: RU | pdf 1.18 Mb

      Small-sized heating boilers of the 20 LX, 20 TLX, 28 LX, 28 TLX series. Installation and operation instructions. Language: RU | pdf 1.60 Mb

      Small-sized heating boilers of the PRO 14 X, 14 TX series. Installation and operation instructions. Language: RU | pdf 1.65 Mb

      Wall-mounted gas boilers of the Therm 20 TLX series; Therm 20 TLXZ; Therm 20 TCX; Therm 28 TLX; Therm 28 TLXZ; Therm 28 TCX. Service manual for installation and service organizations Language: RU | pdf 1.74 Mb

      Wall-mounted gas boilers of the Therm Duo 50, Therm Duo 50T series. Service manual for installation and service organizations Language: RU | pdf 1.60 Mb

      Wall-mounted gas boiler Therm Trio 90. Service manual for installation and service organizations Language: RU | pdf 955.70 Kb

      The procedure for carrying out work when commissioning boilers with automatic equipment DIMS 01-TH01. For authorized Thermona service personnel only. Language: RU | pdf 1.94 Mb

      The procedure for carrying out work during the annual service inspection of a boiler with automatic control DIMS 01-TH01. For authorized Thermona service personnel only. Language: RU | pdf 3.00 Mb

  • OPERATING INSTRUCTIONS FOR HEATING DEVICE “KOLVI-TERMONA” 50 CE(M), 100 CE(M)

    GENERAL PROVISIONS

    1.1. Boiler 50 CE(M), 100 CE(M) “Kolvi-termona” is a gas heating boiler with a cast iron heat exchanger, running on natural gas.

    1.2. The boiler is equipped with a smoke thermostat, which turns off the gas supply to the burner in case of ineffective draft.

    1.3. Kolvi-Termon boilers operate at one power value and turn off when the specified parameters are reached in the heated circuit. The boiler is turned on only at the moment when the need for thermal power arises; This results in fuel savings.

    1.4. Technical specifications.

    Rated thermal power, kW. - 49 (98)

    Supply voltage, V - 230 V

    Working pressure, bar - 3

    Water temperature, C - 90

    Maximum flow

    Natural gas nm/h - 5.7 (11.4)

    Weight, kg - 174 (340)

    1.5.Device structure.

    The structure of the device and its components are shown in Figure 1.

    Figure 1. Main elements of the boiler: 1 – draft sensor; 2 – connection pipe for the return pipeline of the heating system; 3 – connection pipe for the supply pipeline of the boiler heating system; 4 – control panel; 5 – modulation automation; 6 – side wall of the casing; 7 – pilot burner; 8 – ignition electrode; 9 – ionized electrode; 10 – front sheet of the gas burner device; 11 – main burners; 12 – gas manifold; 13 – gas reducer; 14 – top panel of the casing; 15 – pressure meter; 16 – liquid crystal display; 17 – pipe for connection to the chimney; 18 - gas supply pipeline to the igniter; 19- gas supply pipeline to the main burner; 20 – rear casing sheet; 21 – temperature sensor; 22 - thermal insulation; 23 – smoke exhaust attachment; 24 – DHW circuit pump; 25 – high-speed water heater; 26 – DHW switch-off sensor; 27 – DHW thermostat; 28 – DHW temperature sensor.

    I.PREPARING THE BOILER FOR OPERATION.

    I.1. Before putting the boiler into operation, you must:

    Ventilate the room for 15 minutes;

    Check the tightness of the heating system and the apparatus;

    Open shut-off valves in the heating system;

    Check for the presence of draft; to do this, bring a lit match to the hole on the panel of the gas burner device between the main burners; if there is draft, the flame of the match will be drawn into the firebox;

    Check the tightness of the gas pipeline;

    Open the gas tap in front of the device;

    II.TURNING THE BOILER INTO OPERATION.

    II.1. Procedure for starting the boiler:

    Connect the device to the electrical network by turning on the main switch (or plug connector). At the same time, the signal light pos. 5 (Fig. 1);

    Device temperature regulator on the control panel pos. 4 (Fig. 1) turn clockwise to the right extreme position;

    Turn the operating mode switch clockwise on the control panel pos. 4 (Fig. 1). In this case, an electric spark ignition of the gas in the combustion chamber should occur, which can be visually observed through the viewing window on the front wall of the apparatus;

    If any malfunctions occur in the operation of the device, its emergency stop, the warning light on the display lights up, pos. 16 (Fig. 1), which signals that the electronics failed to ignite the flame in the burner. To return to operating condition, you need to briefly turn the switch on the control panel pos. 4 (Fig. 1) clockwise to the extreme right position.

    If the device fails again, it must be turned off until the cause of the failure is determined.

    The heating temperature setting button on the control panel pos. 4 (Fig. 1) on the control panel set the required temperature in the heated rooms. The set temperature of the heated rooms will be maintained automatically.

    III. STOPPING THE BOILER

    III.1. To turn off the boiler for a long time (summer period), it is necessary to perform the following operations:

    Turn off the power to the boiler using the general switch;

    Close the gas valve in front of the device;

    Close the taps on the supply and return pipelines of the heating system.

    III.2. To turn off the boiler for a short time, it is necessary to perform the following operations:

    Switch the operating parameters button on the control panel pos. 4 (Fig. 1). At the same time, the signal lamp on the display, pos. 16 (Fig. 1), which indicates that the device is in operation and the flame is burning.


    Gas heating boilers Vaillant
    Models: floor-standing Atmovit exclusiv, wall-mounted condensing Ecotec plus. Service, maintenance, settings of functional components. Hydraulic diagrams.
    Ariston gas wall boilers
    Models Clas, Clas Evo, Genus. Recommendations for repair, maintenance and service. Elimination of errors and malfunctions. Setting and adjustment methods.
    Gas boilers Immergaz
    Models Eolo Star, Eolo Mini, Nike Star, Nike Mini, Mithos. Repairs and adjustments. Installation, installation and connection. Settings of operating modes and additional equipment.
    Boilers Kentatsu Furst
    Wall-mounted models Nobby Smart. Condensing Smart Condens. Floor standing Sigma, Kobold. Solid fuel Elegant, Vulkan. Malfunctions and error codes. Description and characteristics.

    Thermon boilers - Troubleshooting

    I have a Thermona therm 14 TCL double-circuit boiler. Lately he has started supplying too cold water to the hot water supply (heating is not going well). Using the knob on the front panel, I regulate the water supply to the hot water supply to maximum, but one or two LEDs light up, very rarely three. I tried reducing the water pressure, but it didn't help. This problem happens periodically (not always). If you switch the hot water tap several times in the on/off positions, the device starts to work as expected. I would like to note right away that the degree of contamination of the heat exchanger is not high, since last summer I removed and checked it. It was perfectly clean, and this was after 7 years of work. What should you pay attention to first to solve this problem?

    According to the passport data, this boiler is capable of heating water at 25C with a flow rate of 7-7.5 liters. If the tap water coming to you is about 5-10 degrees, then the maximum possible heating will be no more than 30C (only one electrode will burn on the panel). By adjusting the flow rate, you can increase the temperature of the supplied water to 40C, and sometimes up to 50C. But it is important to consider that if you reduce the flow rate to 3 liters per minute or less, the flow sensor in the DHW circuit may not work and the burner will automatically turn off.

    After installing the Thermon gas wall-mounted boiler, the hot water supply stopped working. We implement it quite simply: water is supplied to the tap through a single heat exchanger. The heating circuit operates, turns on and heats up three times. If you open the DHW tap, error F1 appears on the display. That is, in his opinion, there is a flow, but there is no ignition. Despite the fact that with heating everything is fine. I will also note that if the tap is opened, then when it is heating, it turns off. This means that there is still a flow, otherwise the unit would not react like that. For me, this situation is not clear: there is ignition, there is also flow, but the device does not work correctly. Tried unplugging
    I did a reboot, even turned the plug over. Did not help. Although the device is supplied with good power, since it is connected through a stabilizer.

    In my opinion, this malfunction can occur in two cases: In the heat exchanger operating on the DHW circuit, some deposits have appeared that interfere with the normal flow in the system. The temperature sensor installed on the DHW circuit does not work correctly, namely, it greatly overestimates its value. Although, it is possible that there are two problems at the same time.

    We installed and put into operation a therm duo 50 gas boiler. The following problem arose. When starting up, a spark appears during ignition, which is supplied to the burner and quickly goes out. The display shows error E01. What to do?

    Error E01 most likely means the ignition electrode is dirty. You should clean it carefully with a cloth. The gas pressure may also be weak, and because of this the flame is very low (the device does not see that it is there). The flame sensor insulator may be broken or the control board may have failed. You also need to make sure that there is no leakage to ground anywhere.

    We have a single-circuit gas boiler Thermon 14, operating in summer mode. To turn on the boiler, it repeatedly tries to start with a high temperature in the boiler. How to deal with this?

    The three-way valve may be stuck. To fix the problem, you need to force it to open and close several times. The boiler temperature sensor may be damaged. If it is operating correctly, the three-way valve will not open until the temperature in the device exceeds the temperature in the boiler. The control board may also malfunction, since all algorithms for the operation of the 3-way valve are written in it.

    For some reason, the Thermona therm 35 gas boiler installed on the floor constantly goes out for no reason. The error can only be eliminated if a fan is directed at it. What is this connected with?

    Most likely, in the room where it is installed there is not enough air for the flame to burn. Or the ionization sensor itself is clogged. I have listed the two most common reasons, but there may be something else at play here.

    Thermon 45 is in operation. Yesterday the following problem occurred: the device stopped by mistake “heating water sensor failure.” Do I now need to drain all the water from the system for repairs, and how can I repair the sensor itself?

    Most likely, it was caused by error E04 (damage to the heating temperature sensor). The presence of water in the heating system does not interfere with its replacement. You just need to close the shut-off valves. But the following malfunctions are also possible: a short circuit in the circuit, a dirty dirt filter, a breakdown or incorrect operation of the pump. Because of this, the device overheated from the hot water circulating in the system.

    If the Thermona 28 gas boiler breaks down, error E06 appears on the display. The instructions say that the problem is with the thermostat. Where is it located to replace the sensor?

    Error E06 means that an emergency shutdown occurred due to overheating (emergency thermostat). Poor circulation in the heating system is also possible. If something happened to the hydraulics of the unit itself, it will also show this particular error. Check the filter, correct operation of the pump and sensor.

    Thermona TCL-28, during operation, often began to show error E2. In addition, his pump burned out. Now it is necessary to flush the heating system, adjust and configure the entire device. Why did this happen, and what is the best way to perform the above procedures?

    Error E2 is often indicated by low water pressure in the OS. There may be several reasons for this: a broken expansion tank or some kind of water leak in the system.

    A 20 kW gas boiler is installed. When the hot water supply is turned on, it displays error E01. Then the scoreboard goes out and there are no signs of life. What could have broken?

    It is possible that the ionization sensor touches the housing, thereby shorting the system. Another option: low current on the gas valve control coil. The tipping sensor may also be broken. And, as the most likely option, the control board of the device itself does not work.

    We installed a Thermon gas wall-mounted boiler. When starting, it appears that work has begun, but the heating water supply pump does not start. After a while he stops. What could be wrong with him?

    If we take the principle of operation of wall-mounted boilers, then they should be established that if the circulation pump is not working, they do not even start. You need to somehow start the pump, then the unit will not stop in case of an emergency. On the back surface of the pump you need to open the plug with a screwdriver and slightly turn the armature. In this case, the device must be turned off. Perhaps the anchor is simply stuck to the surface and needs a little help.

    We have a Thermon Duo 50 boiler installed. Error E01 occurs periodically, which entails turning off the device. You can only start it by force, or by turning on the restoration of the ignition system. After that, it works in standard mode (from 30 minutes a day, approximately). I checked the injectors and ignition electrodes. They are not contaminated. I called the service technicians, and they expressed their version - the processor was faulty. Representatives of the gas service have their own version. They are sure that the reason lies in an airlock (my site is located at the very end of the gas pipeline, then there is a dead end). My neighbors don't have these problems. Tell me, what's really going on with my device?

    Your mistake is the most common with gas boilers. And there are a huge number of reasons for its appearance. These could be “dips” in the power supply voltage, problems with gas, breakdowns of the ignition and flame control electrodes, problems with the control board, oxidized contacts and much more.

    I installed a Therm 50 boiler. Until recently, there were no complaints about its performance. However, recently it had to be turned off for 4 days. And now I can't get it to work. A spark fires for 20-30 seconds, and then the emergency light flashes and it never lights up. The error resets, but it doesn't go beyond a spark. The device is connected to the machine. Everything looks fine, there is gas. What could it be?

    According to the PUE standards, a plug must be mounted so that visible disconnection of contacts can be made. You have installed a unit that depends on the phase. Try swapping phase and zero.

    Three therm boilers have been in operation for a long time and are operating successfully - two 28 TLX in cascade and one 32 TCLN. Their first pair in 5 years of work did not create a single problem. Maintenance (disassembly and cleaning, as well as adjustment) is carried out by me approximately once a year. More often there is no need. But I can’t cope with 32 TCLN. I can't even turn off the equithermal mode. It was possible to put it back into operation after disconnecting the sensor. I simply don’t pay attention to the error that occurs. How can I access the service menu of this device?

    To enter the service menu, you need to set all knobs to 7 o’clock, and then turn off the power to the unit itself. When turned on again, it will automatically start the self-diagnosis mode, and then display “CC” on the display for a couple of seconds. If this happens, then everything worked out and the weather-compensated mode is disabled. After this, by turning the knobs you can adjust it as required. Next, unplug it from the outlet.
    Disconnect the sensor from the automation board by disconnecting the valve. You set the knobs on the control panel and return the power supply. Within 30 seconds the automation will perform a self-diagnosis.

    The pressure gauge on the front panel of Thermon 14 began to show very large numbers. However, his work has not changed - everything is as usual. What could be causing this and is it necessary to make repairs?

    This pressure gauge has nothing to do with the operation of the device. It only records the water pressure in it. The readings from this thermometer can be compared with any other pressure gauge in the system (if available).

    When I start the Thermona 45 gas boiler, the following happens: the piez starts to work, but when I switch to the start mode, it goes out. What could it be?

    Most likely, the flame generator has failed. This is the most common reason. But it is also worth checking the draft in the chimney, as well as the ignition nozzles for cleanliness.

    I want to install control of a three-way valve for domestic hot water on the Therm 28 LX boiler using its board. Tell me if this connection and operation will be the same as in the description for LXZ. Or will the coolant stop when switching?

    The algorithm is the same.

    I use a 28 LXZ turbocharged gas boiler. Lately, two errors have been appearing: E01 - constantly, E08 - much less often. When I clear the errors, its operation is restored for a while. The device itself has been serviced quite often. Can I fix this problem myself, or will I need specialists?

    The fan and chimney need to be cleaned. If this does not help, you will need to replace the monostat.

    My device worked perfectly, the service was always carried out on time. And recently, error E01 began to appear. And yesterday E07 was added to it. What happened to him?

    Judging by the errors, there are problems with its ignition, with the chimney, or a breakdown of the monostat. Perhaps your supply ventilation is installed incorrectly or your chimney is frozen.

    For some reason my boiler suddenly stopped due to error E06. How to fix it?

    Error E06 corresponds to emergency overheating of the coolant. You need to check the dirt filter first, because if it is heavily clogged with dirt, the circulation of water in the system is disrupted. Look for the filter on the return pipe between the two valves. Take it apart and clean it.

    This error indicates that when water is heated, it overheats. One possible reason may be a breakdown of the temperature sensor responsible for heating the water. The heat exchanger may also be “clogged” with scale.

    Please tell me how you can regulate the temperature of hot water in model 28 LXZ 10. The knob located on the control panel does not work, and when the master made the settings, he did something inside under the lid. I needed to change the settings, but I don't remember how to do it.

    Remove the front cover of the device. On the bar below it you need to find a hole in which the slot of the DHW thermostat is visible.

    The Thermona 23 tcl worked for five days without any breakdowns or any comments. A couple of weeks ago the pressure on the pressure gauge rose to 2.5, and the explosion valve began to leak. How can I find out: I have a problem with the heat exchanger or with the make-up tap. Finding out the causes of the problem, I learned that my unit was equipped with a heat exchanger made by the Italian company MUT. And as I read, there are very bad reviews about it. Heat exchanger, what good and trusted company can I replace it with?

    It is necessary to set the air pressure in the expansion tank specified by the manufacturer. About 80-90% of boilers are manufactured without an integrated make-up line.

    I have a 14 TCL boiler installed. When you turn it on, for some reason the fan does not start, but it stops on its own due to an accident. An inspection of the device did not reveal any visible wire breaks. The vacuum relay was recently replaced. What else could be the cause of this problem?

    Your model has a two-position vacuum relay. And it is this that commands the closing and opening of contacts (features of operation depend on the model itself). Since you have ruled out a problem with the relay, the breakdown is most likely in the control board.

    Thermon boiler 28 is connected. Lately there has been a problem during startup. If it has been turned off for a long time, then upon startup it works for exactly 10 seconds and then turns off.

    You have a device with natural draft installed. For their correct operation, it is very important that the chimney is in good condition. It's possible your stall sensor is tripping and that's why it stops when it crashes. Then, after it cools down, it becomes possible to start again. Check the chimney for permeability and ensure better air supply to the boiler room.

    Thermon boiler 14 is faulty. When looking for a possible breakdown, I checked everything I could, but did not find the cause of the damage. The only thing I noticed was that for some reason the burner flame was yellow. Could it be a gas quality problem?

    Check the inlet gas supply pressure (it is probably insufficient), or you have problems with the air supply. Once again you need to check the device for damage.

    The Thermon double-circuit boiler (28 kW) broke down. Doesn't heat water. What could be broken in it? And how much can repairs cost?

    An unexpected stoppage of DHW operation indicates that the flow meter is broken or the heat exchanger is heavily contaminated. Check the operation of the flow sensor and, if necessary, install a new sensor.

    The boiler pressure gauge shows that the pressure in the tank is too high. But everything is normal on the batteries, in the heating system, and the pressure. Is it possible that the pressure gauge itself is dirty? Can it be replaced if it breaks?

    If the pressure in the device really exceeded the permissible standards, its emergency stop would have triggered. The pressure gauge can be checked as follows: release all pressure from the device and look at the readings. Its arrow should show 0. We also advise you to check the dirt filter, since it is its cleanliness that directly affects the readings of the pressure gauge on the unit. If you need to change the pressure gauge itself, be prepared for the fact that you will have to drain the water from it.

    Thermon boiler 50 stopped supplying hot water. Moreover, cold water comes in, but nothing comes out at all. What to do?

    If water enters the hot water supply but does not come out, you definitely need to check the heat exchanger. It is also possible that the water supply is mechanically cut off somewhere. Perhaps the gasket was squeezed out and clogged the passages in the heat exchanger. Try applying water in the opposite direction.

    We installed the Thermon 14 wall mounted boiler. When we try to start it, it stops after three seconds. Previously, a mechanical blow to the device helped. Now this doesn't work either. What is the reason for the breakdown?

    If you believe your description, then there is a loose contact on the board or some other place. Check the electrical system, clean and correct all contacts on the board.

    Model 28 tlxz constantly keeps the burner at maximum power and does not try to control it. Maybe it's worth checking the gas valve modulation coil? How to do it? How should the circuit be closed: maximum or minimum?

    The coil cannot change its state; it is not a relay. Its main property is the presence of resistance. If the valve operates at maximum, then everything is fine. There is a possibility of the valve sticking open, but it is very small. Check the board.

    The device constantly stops due to an emergency when the DHW circuit is operating. What could be the problem?

    Check the flow sensor or secondary heat exchanger for proper flow.