Fire alarm installation services. Fire alarm installation price. Turnkey fire alarm installation price. Commissioning work when putting the fire alarm system into operation
Ecolife Group carries out installation of automatic fire alarms and turnkey fire extinguishing systems for enterprises, office and shopping centers, schools and sports facilities, apartments, country houses, cottages and other objects. The company also accepts Maintenance and repairs all types of equipment fire alarm.
Contract for the installation of fire alarms, a complete set of documents
Our company works with legal and individuals. We conclude an agreement for all services provided, which is a document that clearly defines the cost and timing of the work. Pre-agreed terms reduce risks for both parties, and also ensure the benefits of the transaction for the seller and buyer.
Signing the certificates of completed work and acceptance and transfer of equipment means the successful completion of the work. We provide a full package of documents, including invoices, acts, invoices and cash receipts for cash payments, commissioning reports, and system settings. After completing the work, we continue to work with you as a consultant and service organization.
An engineer’s visit to calculate the cost of work is free of charge.
Fire alarm installation cost
Name of works | Unit change | Cost, rub |
Installation with connection of a control panel | PC. | 1500 |
Installation of intermediate devices for the number of beams | PC. | 1200 |
Installation with connection of the internal power supply | PC. | 500 |
Installation with connection of an external power supply | PC. | 900 |
Control panel | PC. | 1300 |
Two-Wire Link Controller | PC. | 900 |
Relay block | PC. | 900 |
Fire extinguishing indication unit | PC. | 800 |
Fire extinguishing and control panel | PC. | 1500 |
Interface converter | PC. | 700 |
Branching-isolating block | PC. | 400 |
Address expander for 8 addresses | PC. | 700 |
Address expander for 2 addresses | PC. | 400 |
Redundant power supply RIP | PC. | 1200 |
Battery 7 Ah | PC. | 350 |
Addressable analogue fire detector | PC. | 600 |
Fire detector thermal addressable analogue | PC. | 600 |
Analogue smoke detector | PC. | 450 |
Fire detector thermal analogue | PC. | 400 |
Manual addressable fire detector IPR-513-ZA isp.02 | PC. | 500 |
Linear fire smoke detector | PC. | 900 |
Cost of commissioning of OPS systems | set | negotiable |
Corrugated cable laying | ||
Open fastening with tie or bracket | m | 30 |
Behind the false ceiling | m | 30 |
Under the floors | m | 40 |
By trays | m | 50 |
Installation of corrugations with drilling | m | 60 |
Installation of the box with drilling | m | 60 |
in tray | m | 40 |
In a box | m | 20 |
Shaving (concrete, brick, asphalt) | m | 300 |
In the ground | m | 300 |
Tightening the cable into the corrugation | m | 10 |
Drilling holes 10 cm | PC. | 100 |
Difficulty factor | ||
Works | Coefficient | |
Outdoor installation from May to October | 1,2 | |
Outdoor installation from October to May | 1,5 | |
Installation at a height of 3 to 4 meters | 1,2 | |
Installation at a height of 4 to 5 meters | 1,4 | |
Installation at a height of 5 to 6 meters | 1,6 | |
Installation after hours and weekends | 1,3 | |
Installation in rooms with big amount furniture and people | 1,3 |
For calculation exact cost fire alarm installation work, call us or send your existing fire alarm project. We will calculate the cost of alarm installation within a day.
Installation of fire alarm systems is carried out on the basis of approved working (design) documentation.
If it is not available, the engineers of Ecolife Group of Companies are ready to perform for you design work. To do this, we will need floor plans of your facility and technical requirements in the form of a technical specification for the design of a fire alarm.
After completing the project, our specialists will begin work on installing an automatic fire alarm system. Thus, Ecolife Group of Companies carries out the design and installation of fire alarm systems in the complex.
Our specialist goes to the site free of charge to calculate the price of a fire alarm, draw up a Commercial Proposal and an Agreement. Contact us by phone, e-mail or the order form on the website.
Fire alarm installation: how we work
Fire alarm installation: stages of work
When the design work is completed, we can assume that an automatic fire alarm system already exists, albeit only in theory for now. All technical decisions have already been made, the type of alarm system has been selected, necessary equipment and materials selected. This system is unique and it will not fit any other object. The next stage is installation work, which will put the plan into practice and “breathe life” into the most important human protection system.
That's why, installation of fire alarm systems- not only expensive, but also the most critical stage of work. It requires attention and control not only from the contractor, but also from the owner of the facility.
Any construction and installation work can be divided into two components:
1. Direct execution of work;
2. Preparation of acceptance documentation.
It cannot be said that one is more important than the other. Both components are needed for further stable operation of the system and its operation. Before handing over the completed work, the customer must have a fully tested and functioning fire alarm system and several folders with documentation.
As in the case of design, it would be nice for the customer to have in his arsenal a person who is able to understand all this and control the process. Large companies have no problem with this. An engineer is appointed by order, or even an entire engineering organization is contracted to carry out technical supervision over the work and documentation. If this is a one-time job for the customer, or there is simply no way to hire someone additionally, then key points you'll have to figure it out on your own.
So where does the installation of a fire alarm begin?
The installation process can be divided into several stages:
- Selecting a contracting company;
- Inspection of the object and conclusion of the contract;
- Purchase of equipment and materials;
- Performance electrical installation work;
- Performance commissioning works.
Fire alarm installation: choosing a contractor
When performing installation work, the most important thing for the customer is preparation. Find a company that will meet all the requirements, discuss all the subtleties and features of the object - this must be done before signing an agreement or contract. During the execution of work, it will only be possible to monitor compliance with all contractual obligations without interfering with the production process.
The choice among companies that install fire alarms is quite wide. Even in comparatively small town you can find a couple of such organizations. In order for the company to carry out this type activity, it must at least have a license from the Ministry of Emergency Situations of the Russian Federation.
IN Lately specialized organizations become members of Self-Regulatory Organizations (SROs) and receive a “Certificate of Admission to Certain Types of Work.” In this certificate they are interested in the section “Installation of means fire protection" This certificate gives the right to carry out work on installing fire alarms in strict accordance with certain cases. Therefore, if you need to install an alarm in any “standard” operating building (shop, office, hotel), then having such a certificate is not necessary. But, if the company you choose has it, then this fact can definitely be considered an advantage.
Site inspection and conclusion of a contract for the installation of a fire alarm
Now a little about what is required from the customer before concluding a contract for installation work.
Firstly, you should have a project at stage “P” in your hands (or on electronic media). Based on this project installation organization will be able to calculate the price of equipment, as well as the cost of construction, installation and commissioning works. If you have a project in in electronic format, then you can just call several companies, send them the project by email and ask them to submit Commercial offer. In this case, you will not have to waste time on meetings or travel. And the proposals received can be compared in terms of cost and other conditions (work completion time, presence/absence of advance payment, etc.) at a time convenient for you.
Secondly, the customer needs to imagine in detail how the work will be performed from an administrative and economic point of view. You can even draw up a small document with your requirements for the work. And such a document will be called, as in the case of design, “Technical Specifications”. Samples of such a document can be easily found on the World Wide Web. In this document you can, for example, indicate specific hours for performing work. If the object of protection is a hotel, then this requirement will be relevant and justified. Also, one of the requirements may be cleaning of premises (dry or wet) at the end of each working day, with determination of the location for storing waste. Or you, as a customer, can request that a responsible employee from the company be permanently present at your site so that any technical or organizational issues that arise can be resolved at any time.
Third, it will be extremely useful for both the installation organization and the customer to inspect the site before concluding a contract. The main goal of this event is to check the compliance of the design and actual data of the object. In practice, it happens that from the moment the execution is completed design work A significant period of time may pass before the start of alarm installation work. This happens especially often at facilities under construction. And during this period, some architectural changes may occur at the site, which they simply forgot to include in the automatic fire alarm project. IN similar cases preliminary examination can be extremely important.
For the customer it is also great way get to know a potential contractor better and have the opportunity to see him “in action.” A contractor will be able to visualize the scale upcoming works and discuss some installation details with the owner of the property.
It is clear that such requirements can lead to an increase in the overall cost of performing the work. But if there are circumstances that you consider extremely important when installing a fire alarm, then they must be conveyed to the contractor. And it is best if your requirements are in writing. In this case, they can be fully transferred to the contract or this Technical Specification can be drawn up as an annex to it.
Fire alarm installation: purchase of equipment and materials
This task can be accomplished in several ways.
First way- supply is entirely handled by the customer. There can be many reasons for such contractual relationships. If during the negotiations the parties came to such a decision, then it is beneficial for them. For the installation organization this is at least convenient:
- no need to spend resources on purchasing and transporting equipment to the site,
- in case of receiving defective or “insufficient” equipment, there is no need to replace it;
This type of cooperation is quite common. In order to buy equipment you do not need any licenses or certificates. But, if the customer decides to take on the role of supplier, then he must understand that any questions regarding the discrepancy between the purchased equipment and the design equipment, as well as possible problems with its replacement or return will fall on his shoulders. If all this does not cause much trouble, then this method can easily be put into practice.
Second way, when the purchase of materials is entrusted to the installation organization, more common. In this case, the installation organization also becomes a supplier for the customer. There are several reasons for this.
Firstly, installation organizations buy equipment for systems fire automatics on an ongoing basis. This means that they know all the nearest trading companies and are guided by the prices of this or that equipment from different sellers. As a result, installation companies have significant discounts from the sellers they work with, so they can also help save your budget.
Secondly, all installation companies have a certain amount of equipment in stock. It is not at all necessary that the installation company will be able to fully provide the facility with everything necessary from its stocks of warehouse equipment. But collecting equipment from your warehouse in order to immediately begin installation work is quite possible. And in a day or two they will be able to deliver everything else directly from the trading company. Convenient, isn't it?
Third, all responsibility for the quality and performance of the equipment will lie with the installation organization. That is, if some equipment turns out to be defective or damaged (which in practice happens much more often than we would like), the installation organization will have to take on the job of replacing it. Moreover, given the availability of a warehouse, most often the replacement occurs instantly and the installation process does not have to be stopped.
Third way Most often used by large companies. It consists of organizing a tender for the purchase of equipment. If you do not have such experience, you may encounter a number of serious difficulties. Probably the most verified way to organize a purchase would be to contact professional companies, who not only carry out these purchases, but will also be able to advise in detail. If there are well-designed technical requirements to purchase, you can achieve very serious cost savings. Otherwise, you will still have to spend time and human resources to monitor compliance with the terms of the supply agreement.
Carrying out installation work on site. Alarm installation
After preparatory work You can proceed with the installation.
It's no secret that installing an automatic fire alarm is a process that must meet a huge number of requirements. If the customer has specialists who can monitor the installation process, this will greatly simplify the control task. If there are no such specialists, they can be hired. And then only administrative functions will remain with the customer.
In addition to design technical solutions and the conditions for performing work dictated by the customer, there are a number of requirements that the installation organization must comply with.
- Since the work is aimed at ensuring fire safety, then they must comply with fire safety standards.
- Installation of an alarm system is a job that is directly related to electrical installation work. And despite the fact that these works mostly relate to low current systems(up to 60 V), they must meet the requirements for electrical installation work.
- Do not forget that installation of a fire alarm is one of the stages of construction. Therefore, the installation of alarm systems must comply with building regulations.
- In addition to all of the above, when working it is necessary to comply with safety precautions and labor protection requirements. There are quite a lot of such requirements. And if the object of protection is a zone of increased danger, then their number increases and becomes tougher at times.
It may seem that so many requirements are simply impossible to meet. But for experienced companies that have been conducting this activity for several years and have equipped fire-fighting automatics several dozen or hundreds of objects, all these norms and rules are very familiar and are carried out at the level of habit. They can competently justify and document every step they take and every action they take. Therefore, when choosing a company as a contractor, do not forget to find out about the experience in this field and the number of completed projects. It would not be superfluous to clarify about working on objects that are similar or similar in their specificity to your object. It is worth noting that installation organizations that care about their reputation prepare separate documents that chronological order reflect the list of iconic objects where the company worked. Such documents are called “Business Reputation”. Customer reviews may be added to this document.
Construction and installation work begins with introductory and initial briefings. Both of them are aimed at ensuring that the work carried out is carried out with maximum attention and is safe for each participant in the production process.
Induction training carried out by the customer. It can take place either orally or in the form of a video presentation. the main objective of this briefing - to convey information about the object, its purpose and features from the point of view safe production installation work. An introductory briefing is carried out by a labor protection engineer or other responsible person who performs these functions on the basis of an order from the manager. After the briefing, each employee puts his signature in the briefing log, thereby confirming its completion.
Initial briefing also carried out on site. Unlike the introductory briefing, it is conducted by a responsible representative of the installation organization. And it is aimed primarily at informing workers about labor protection and safety requirements. When performing electrical installation work, which includes installation of fire alarms, these requirements relate to safety when working with electricity, hand and power tools, rules for working at height, etc. If the object is a high-risk area (gas, oil, metallurgical, etc. industries), then in addition to general rules, instruction is supplemented by cross-industry or highly specialized requirements.
Throughout the entire period of construction and installation work, the customer has the right to monitor and control the process of their implementation. If the customer has questions, he has the right to ask them both orally and in writing. After all, despite the fact that introductory training has been carried out, the customer is responsible for the specialists working at his site. Moreover, the customer has the right to suspend work if he sees violations in their production or non-compliance with labor protection requirements. As a rule, most of these issues are agreed upon through negotiations. In very rare cases, when certain rules are violated systematically, the customer may terminate the contract.
Commissioning work when putting the fire alarm system into operation
After completion of installation work, it is time for commissioning work. The name speaks for itself about its composition. The essence of the work is to launch the mounted system and fix everything possible mistakes installation, malfunctions in the operation of system components, identify possible defective equipment. Also, during commissioning mode, it is necessary to test the system in all operating modes and make sure that it correctly and accurately processes received signals and sent commands.
Commissioning works cannot be underestimated, especially if the object of protection is a large building with many systems associated in their work with fire alarms.
Once the system has been fully checked and tested, it is left on for 72 hours. This period is called the “running period”. The meaning of this practice is to identify malfunctions in the operation of the system or its individual components that did not appear during testing.
It happens, albeit in very rare cases, that a customer hires separate organization to carry out commissioning work. From a legal point of view, this is a completely acceptable measure. But if you look at this from an economic or organizational point of view, then the customer certainly loses. After all, the new contractor will include estimated cost all overhead costs, and to attract him again you will have to carry out a selection, introduce him to the project and the object, draw up technical task and provide instructions. Of course, this will take a lot of time and resources. On the positive side Such a step may only be the need to transfer installation work to a new contractor. That is, one specialized organization will be able to carry out an interim assessment of the work performed by another specialized organization. Otherwise, such a “castling” will only create problems. Therefore, in the vast majority of cases, installation and commissioning work is carried out by one organization.
After completion of the work, the installation organization notifies the customer in writing of readiness for comprehensive testing installed system.
Preparation of acceptance documentation for fire alarms
In order to document the fact of performing any construction and installation work, there is the so-called “Acceptance documentation”. As a rule, it consists of four sections:
- Permitting documentation;
- Working documentation;
- Production documentation;
- Executive documentation.
These sections are compiled on the basis regulatory documents, state standards And building regulations. Depending on the type of work performed, the composition of the documents varies. Each section is compiled into a separate folder and provided with a register of the documents included in it. First of all, the contractor should know how to correctly and competently draw up the Acceptance Documentation. He, in fact, must develop it and sign it by everyone responsible persons involved in the work process. A detailed list of documents included in each section of this set is usually reflected already at the time of drawing up the agreement (contract).
After reading all the above information, it may seem that monitoring the installation of an automatic fire alarm on the part of the customer is an extremely difficult task. Especially for those who are faced with the need to equip a facility with fire-fighting automation for the first time.
Fire alarm installation is one of the most popular services of the Stroy-TK company, a reliable partner in ensuring your safety at a variety of facilities in Moscow and the region.
The professional approach of our specialists, competent design and installation of fire alarms, high quality and the reliability of the equipment used - all this makes cooperation with the company objectively beneficial in all respects.
We specialize in the installation of almost all types of alarm systems existing today, both standard security fire alarms (OPS) and automatic fire alarms (AFS). All technical equipment is characterized by a high degree of reliability and reliability, so you can always be confident in your own safety.
Why do you need a fire protection system?
Human factor, video surveillance system and individual means fire extinguishing systems are mandatory components of the safety of any room, office, building, etc. However, not always all these measures allow you to quickly respond to the threat of fire or penetration and minimize damage.
Modern technologies allow you to almost instantly identify the source of fire, break-in, etc., notify the relevant services about the threat and take measures to eliminate it. Installation security and fire alarm system, and also its maintenance does not require serious energy consumption, which makes them so popular and convenient.
Functions and tasks of the OPS
Modern security and fire alarm systems are a highly efficient unified system that operates autonomously. Installation of APS (automatic fire alarm) allows you to solve a whole range of security problems separate room or an entire building.
- Fire detection– the system, based on specific criteria, determines the occurrence of a fire.
- Collection of information – OPS collects the necessary data and records the processed information.
- Alarm generation– the system generates signals designed to notify everyone in the building about a fire.
- Turning on fire extinguishing systems– generation of commands for activation automatic means to eliminate fire and smoke.
Elements of security and fire alarm systems
The OPS includes many high-precision instruments and technical means, combined into unified system alerts. Depending on the type and purpose, the alarm may include various elements, however, the main functional units can be identified in each of them.
- Control system- this is the “brain” of the OPS, a central computer with specialized software. It is from this control panel that the settings of the entire system are set and its elements are controlled.
- Sensors, detectors and sensors– highly sensitive devices that capture control information various types. They record the fact of a threat (fire, unauthorized entry into the territory, etc.) and transmit the received data to the appropriate nodes.
- Data acquisition and processing equipment– points where primary information from detectors is received.
Turnkey fire alarm installation from Stroy-TK
Installing a warning system is quite a painstaking job, which consists of several stages.
Specialist visit
The development of any security system begins with an assessment of the premises or building where it is required security system. Experienced specialist Stroy-TK company will arrive at the appointed place and collect information.Drafting
In accordance with the specifics of the object, it is developed.Equipment selection
According to the plan, the necessary devices and systems are selected that together can provide a high degree of protection for the facility. Specialists of the Stroy-TK company, within the framework of an individual approach, will select for you only high-quality and reliable elements.Coordination of the project with the customer
At this stage, an estimate is drawn up and a contract is signed. full control from the client's side.Installation
Installation of all systems in accordance with the project.Commissioning works
After the installation of the APS system has been carried out, a comprehensive check of its functioning takes place and delivery to the customer.OPS maintenance
We offer our customers reliable guarantees even after installation.
Installation cost
The cost of installing an alarm system consists of several components: the amount of work, the complexity factor, the presence of additional requirements, etc. Of course it's quite simple system alarm system will cost you much less than a complex alarm system with many functionality and options. The final cost of installation work can be established only after drawing up the project.
Prices for installation and installation of fire alarms
Types of work and services | units measured | Price with VAT |
---|---|---|
General | ||
Departure for site inspection in Moscow | service | 0 |
Departure for site inspection in the Moscow region. | service | 0 |
Preparation of specifications, costing | service | 0 |
OS installation prices | ||
Installing a glass break sensor (GBS) / acoustic detector | PC. | 330 |
Installation of a passive IR sensor (motion sensor) | PC. | 330 |
Installation infrared sensor street | PC. | 780 |
Installing a panic button | PC. | 330 |
Installation of flexible transition | PC. | 93 |
Reader installation | PC. | 210 |
Installation and programming of a keyboard with LCD display | PC. | 980 |
Installation and programming of LED keyboard. | PC. | 600 |
Installation and programming of a wireless magnetic sensor | PC. | 500 |
Installation and programming of a wireless passive IR (volumetric) sensor | PC. | 700 |
Installation and programming of a wireless glass break sensor | PC. | 700 |
Battery installation/replacement | PC. | 100 |
Installation and connection of the control keyboard | PC. | 700 |
Installation and connection of the address expander | PC. | 350 |
Installing an uninterruptible power supply | PC. | 590 |
Installation of magnetic contact sensor (MCS) | PC. | 150 |
Installing a magnetic contact sensor on a breach | PC. | 300 |
Installation of a mortise magnetic contact sensor in a wooden door | PC. | 350 |
Installation of an overhead magnetic contact sensor on a wooden door | PC. | 130 |
Installation of a mortise magnetic contact sensor in a metal door | PC. | 650 |
Installation of an overhead magnetic contact sensor on a metal door | PC. | 360 |
Installing a siren or sounder | PC. | 300 |
Installation and disconnection of the junction box | PC. | 50 |
Installation and connection of the surface vibration/capacitive sensor | PC. | 350 |
Installation and connection of the alarm button | PC. | 350 |
PC. | 1 500 | |
Installation, connection and configuration of an integrated software and hardware complex for fire alarm systems (software on a computer) | service | from 4900 |
Installation and programming of a wireless control panel (arming/disarming, panic button) | PC. | 500 |
Installation and connection of the GSM module | PC. | 550 |
Prices for installation of substation | ||
Installation of smoke and heat detectors | PC. | 350 |
Installation of a manual fire detector (IPR) | PC. | 350 |
Wireless Smoke Detector Installation and Programming | PC. | 500 |
Installation and programming of a wireless manual fire detector (IPR) | PC. | 500 |
Installation/replacement of battery, batteries | PC. | 100 |
Installation and programming of an addressable smoke detector | PC. | 400 |
Installation and programming of an addressable heat detector | PC. | 400 |
Installation and programming of an addressable manual fire detector (IPR) | PC. | 400 |
Installation of a light indicator for the "Exit" sign | PC. | 350 |
Installing a siren/sounder | PC. | 350 |
Installation and connection of the CO sensor ( carbon monoxide) | PC. | 350 |
Installation and connection of a water leakage sensor | PC. | 350 |
Installation, connection and programming of the control panel (VERS, Signal-20) | PC. | 1 500 |
Installation of the control panel | PC. | 700 |
Installing a power supply with battery | PC. | 600 |
Installation of distribution / junction box | PC. | 50 |
Installing a keyboard with LCD display | PC. | 1 000 |
LED Keypad Installation and Programming | PC. | 600 |
Installation and programming of a wireless carbon monoxide (CO) sensor with light indication | PC. | 500 |
Installation and programming of a wireless water leakage monitoring sensor | PC. | 500 |
Installing a wired zone expansion module | PC. | 600 |
Installing a wireless zone expansion module | PC. | 800 |
Installation of Buran powder module | PC. | 650 |
Installation of GSM module | PC. | 550 |
Prices for installation of SOUE | ||
Installation, connection and configuration of a medium power amplifier | PC. | 1 120 |
Installation, connection and configuration of a mounted, wall-mounted loudspeaker | PC. | 1 000 |
Installation and switching of the control device technical means alerts and evacuation | PC. | 1 200 |
Configuring the control device for technical means of warning and evacuation | service | 5 000 |
Installation of in-wall speaker | PC. | 800 |
Installing a wall speaker | PC. | 450 |
Prices for cable work | ||
Cabling open method on brackets (all types of cable, except electrical) | p/m | 30 |
Laying the cable in a corrugated pipe with cable tightening and fastening | p/m | 45 |
Laying cables in a box without installing the box | p/m | 15 |
Cable laying in the groove | p/m | 20 |
Cable installation in a suspended ceiling | p/m | 60 |
Cable laying under a collapsible raised floor/false ceiling | p/m | 20 |
Laying the cable in the tray | p/m | 20 |
Installation of a cable channel for cables on drywall up to 60 mm | p/m | 30 |
Installation of a cable channel for cables on brick, concrete up to 60 mm | p/m | 50 |
Installation of a cable channel for cables on drywall from 60 mm to 100 mm | p/m | 50 |
Installation of a cable channel for cables on brick, concrete up to 60 mm up to 100 mm | p/m | 80 |
Installation of bracket for tray up to 400mm | PC. | 50 |
Installation of a metal tray up to 200 mm wide with bracket fastening | PC. | 150 |
Installation of a metal tray up to 400 mm wide with bracket fastening | PC. | 250 |
Installation of metal boxes on all types of surfaces | p/m | 300 |
Laying a cable overhead line | p/m | 100 |
Laying cables in the ground in warm time of the year | p/m | 250 |
Cable markings | PC. | 5 |
Cable testing | PC. | 10 |
Cable tracing (reel unwinding, marking, length measurements, stretching, cutting) | p/m | 5 |
Prices for gating | ||
Wall chipping monolith/concrete | m.p. | from 150 |
Wall chipping brick/plaster | m.p. | from 100 |
Sealing the grooves (rough) | m.p. | from 50 |
Prices for drilling | ||
Drilling holes in concrete wall O less than 20 mm thick. walls up to 25 cm. | PC. | 100 |
Drilling holes in a brick/wooden wall O less than 20 mm thick. walls up to 25 cm. | PC. | 50 |
Drilling holes in a concrete wall O less than 20 mm thick. walls more than 25 cm. | PC. | 150 |
Drilling holes in a brick/wooden wall O less than 20 mm thick. more than 25 cm. | PC. | 100 |
Drilling holes in concrete/brick wall O over 20 mm thick. walls more than 25 cm. | PC. | 700 |
Punching of interfloor channel O up to 25 mm | PC. | 350 |
Punching of interfloor channel O from 25 mm | PC. | 700 |
Repair prices | ||
Replacing fuses without soldering | PC. | 50 |
Wiring of connectors, connections, switching in junction boxes. | PC. | 150 |
Replacing the DVR hard drive | PC. | 500 |
Metering electrical capacity and cleaning battery contacts | service | 100 |
Cleaning burnt contact groups of relay elements | service | 100 |
Programming OPS modules | service | 2 400 |
Programming and setting up a computer video surveillance system | service | 2 000 |
Checking system performance after repair | service | 1 500 |
Prices for dismantling work | ||
Dismantling of fire alarms: smoke, thermal sensors, manual call points, "Exit" sign, sirens, | PC. | 50 |
Dismantling of security alarms: motion sensors, glass break sensors, KTS | PC. | 50 |
Dismantling the magnetic contact sensor (MCS) | PC. | 35 |
Dismantling of switching equipment | PC. | 150 |
Dismantling the control/security/fire panel | PC. | 200 |
Dismantling a low-current cable | PC. | 15 |
Dismantling the cable channel (duct) | PC. | 15 |
Dismantling a cable laid in an open way | p/m | 10 |
Removing the power supply | PC. | 150 |
Removing the GSM module | PC. | 200 |
Dismantling a siren / outdoor sounder | PC. | 200 |
*Prices for all types of work are valid for work performed at a height of up to 3 meters. When installing equipment at height, a multiplying factor is applied. |
For getting detailed information For questions about installing a fire alarm system, please contact our office by phone
Today there are several types of systems. They are classified depending on the characteristics of the signal and necessary conditions for him. So.
- Threshold systems. The sensor contains certain threshold values; if they are exceeded, the system will work;
- The second type of sensors works thanks to a computer system that automatically takes readings. This type of system is called targeted-survey.
- Finally, the most effective and most expensive type is analog. Without exception, all data (and not just critical indicators) is received on a computer. At the slightest change, the system immediately responds. Moreover, when the threat is low, the signal is turned on, and when the threat is high, automatic system extinguishing the fire.
We will not begin any installation work without checking the state of the power supply and network cables. Without their adequate operation, not a single signal will reach the computer panel.
Fire system installation cost.
The exact amount will be announced by the surveyor after he arrives at the site and draws up a project and estimate. Prices for the most inexpensive systems start from 500 rubles. Analogue - from 1500 rubles.
The cost is affected by the amount of work, conditions, remoteness of the object, urgency of order fulfillment (if you wish). In any case: before signing the contract, we will show you the estimate. If you are satisfied with everything, you sign. And we start working.