Operation of Zota Lux electric boilers

Check the reliability of the protective grounding.

Fill the heating system and electric boiler Zota Lux 9/12 with water, ensuring that no water gets inside the casing.

Check the reliability and tightness of all water circuit connections.

For a hot water system, open the valve on the cold water supply line.

Turn on the input machine to the “ON” position, while the “NETWORK” LED lights up on the front panel and the digital indicator displays the current water temperature in the system.

If, after turning on the Zota Lux 9/12 electric boiler, the “EMERGENCY” indicator lights up and the digital indicator shows a fault code, then several types of faults are possible:

- (H-1) break in the water temperature sensor;

- (H-2) short circuit of the water temperature sensor;

- (H-3) incorrect polarity of the water temperature sensor;

- (H-4) the pump protection circuit breaker is disabled;

- (N-5) there is no water in the electric boiler;

- (H-6) water temperature is above 95C or the overheating sensor is faulty.

At the same time as the fault type is displayed, different audible signals will sound corresponding to each fault type.

Fig.2. Location of controls on the front panel of the Zota Lux electric boiler

1 - mains voltage indicator, 2 - emergency mode indicator, 3 - digital indicator, 4 - water heater power display mode indicator, 5 - coolant temperature display mode indicator, 6 - room air temperature display mode indicator, 7 - outdoor air temperature display mode indicator , 8 - indicator of the mode of displaying the operation of the internal thermostat, 9 - indicator of the thermostat operation 10,11,12 - indicators for turning on the power stages of the water heater, 13 - indicator of the pump operation, 14 - button for entering the operating modes of the water heater,
15 - button to increase readings, 16 - button to decrease readings, 17 - GSM module operation indicator

Using the buttons marked T7, you can change the information displayed on the digital indicator. When these buttons are pressed, the indicator sequentially displays the current values: maximum power of the Zota Lux 6/15 electric boiler, water temperature, indoor air temperature, outdoor air temperature, internal thermostat operating mode.

Each press is accompanied by a short beep. At the same time, indicators (4), (5), (6), (7), (8), Fig. 2 light up, respectively, indicating the display of the current value.

To change the setting of the displayed parameter, you must press the enter button, the indicator will start flashing and, using the U and T buttons, you can change the settings of these parameters.

It must be remembered that when setting the temperature of the room air or water to a lower value than what is currently available in the room or heating system, the heating will not turn on until the temperature of the water and air drops below the set values. If you set the power to 0 kW, the heating will also not turn on.

In the outdoor air temperature indication mode, the value of this temperature affects the operation of the boiler only if the weather-dependent control mode is enabled. In this mode you can set the temperature when the heating is not turned on. When the weather-compensated control mode is disabled, the enter button does not work.

To prevent accidental changes in water temperature, room air temperature and power settings, the electric boiler is equipped with a lock.

To turn on the blocking, you must press and hold the button for 10 seconds, after which (C-1) is displayed on the indicator for a while and the Zota Lux electric boiler goes into blocking mode.

In this mode, you can only view water, air and power temperatures; changing settings is impossible. To disable the lock, press and hold the button for 10 seconds, the indicator shows (C-2) and the electric boiler goes into normal operation.

To return to the factory settings, hold down the U and UT buttons and turn on the boiler. The indicator will show SBR and a sound signal will sound. The following settings will change: power - 0, water - 75 ° C, air - 23 ° C, thermostat - 0. The table's factory settings will also be restored.

If the digital indicator shows a malfunction symbol in the indoor or outdoor temperature display mode, you must correct the malfunction by following the instructions about the type of malfunction.

The absence of indoor and outdoor air temperature sensors does not affect the operation of the boiler and adjustment is made only by the temperature of the water in the boiler. If there is no outdoor air temperature sensor, the weather-compensated control mode does not work.

When water is heated above 95C, emergency temperature protection is activated, the “EMERGENCY” indicator (2), Fig. 2 lights up, the heating is turned off, and the digital indicator shows the fault code /H-6/. When the water cools by about 20C, the heating turns on again.

To protect the heating elements, there is a water level sensor, which is triggered when the water level in the Zota Lux electric boiler drops, the “EMERGENCY” indicator (2) Fig. 2 lights up, the inscription /N-5/ is displayed on the digital indicator and the heating is turned off.

The circulation pump can operate in two operating modes: constant, without shutting off, and periodic, with the pump turning off. When the circulation pump is constantly running, the indicator (13), Fig. 2, “PUMP ON” lights up.

The pump is connected through a circuit breaker, and when the machine is turned off (for example, when short circuit pump circuit), supply voltage is not supplied to the pump, the indicator (13) goes out, the inscription /N-4/ lights up on the digital indicator and the heating is turned off.

In the case of pump operation in periodic mode, shutdown occurs after turning off all heating stages and holding for a certain time. In this case, it is necessary that the temperature of the coolant drops below 70°C; if the temperature is higher, the pump operates continuously until the temperature drops.

In this mode, when the pump is running, the “PUMP ON” indicator (13) lights up; if the pump is turned off, the indicator goes out. You can set the pump operating mode in the user menu.

The built-in thermostat works in three advances installed programs, which are set in the MODE menu:

Mode 1 (working day)
- Mode 2 (day off)
- Mode 3 (weekly cycle)
- Mode 0 (thermostat off)

In order to turn the thermostat on or off, you need to use the buttons marked with the symbols U and U7, select the mode menu item, press the enter button, select the number 0-1-2-3 and press the enter button again. When the internal thermostat is turned on, the “THERMOSTAT” indicator (9) lights up constantly. If mode 0 is selected, the indicator goes off.

When an external programmable thermostat is connected to blocks T1, T2, heating in the boiler is turned on if the thermostat relay contacts are closed. When the contacts are opened, the “THERMOSTAT” indicator (9), Fig. 2, begins to flash periodically, and the heating of all stages is turned off simultaneously.

An external thermostat can be used as a time-programmable timer that turns the heating on and off at a programmed time. In this case, the room air temperature sensor is connected to the boiler and operates in normal mode.

If an external thermostat is used as a timer with adjustment of the room temperature schedule according to a specific program, then the room air temperature sensor ( pads A-,B+), must be disabled. When connecting an external thermostat, the internal one must be turned off to ensure correct operation of the electric boiler.

For proper operation internal thermostat of the electric boiler Zota Lux 6/15 in accordance with the specified modes, you must set the internal clock in accordance with your time zone. If the time differs from the one set at the factory, it must be reset in the user menu.

The weather-dependent control mode, which is provided in the water heater, is used to regulate the temperature of the coolant in the heating circuit depending on the outside temperature if it is not possible to regulate the temperature using the room temperature sensor.

The room temperature sensor is not connected. When a room temperature sensor is connected, it works as a limiter maximum temperature in room.

When operating in this mode, the temperature of the coolant in the heating circuit is regulated according to a schedule. The graph has several lines, the slope of which takes into account the heat loss of the building.

If the building is not insulated enough, to compensate for heat loss, a slightly higher temperature of the coolant in the heating circuit will be required and, accordingly, the slope of the line will be steep. If the thermal insulation of the house is good, then the slope of the line is gentler.

To enable weather-dependent regulation, you must select the slope coefficient of the control line from the presented graphs and write it into the water heater’s memory in the user menu. This graph was constructed taking into account the condition that the heating does not turn on when the air temperature outside reaches +20C and, accordingly, the air temperature in the room is also equal to the outside temperature.

This temperature is stored in the water heater's memory at the manufacturer's factory. To change this temperature, you need to go to the menu displaying the temperature of the outside air sensor, press the enter button and use the and buttons to set the required temperature.

After that, press the enter button again. To disable weather-dependent regulation, it is necessary to set the coefficient K=0 in item P-17 of the user menu.

To connect the monitoring and control function using the GSM module, you need to go to the settings menu and set the menu value P-18 to “1”. This will allow the operations of adding and deleting numbers from which it will be possible to control the device. After registering the module in the mobile operator’s network, the GSM module operation indicator (17) on the front panel of the control unit blinks.

When the Zota Lux electric boiler is operating, the number of heating elements turned on is selected automatically depending on the difference between the set water and air temperatures and those currently available in the heating system and in the room.

When limited maximum power, accordingly, the number of operating stages is reduced to 2 or 1. When the power is set to 0 kW, the stages are not turned on.

To ensure the same operating time for each heating element over the entire period of operation of the boiler, the included heating elements are automatically sorted according to a specific program. At the same time, the life of the heating elements increases significantly.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

__________________________________________________________________________

OPERATION AND REPAIR OF BOILERS

Domestic consumers have long appreciated the products of the Krasnoyarsk Heating Equipment and Automation Plant, which in turn is a production division of the huge Krasnoyarskenergokomplekt company. The plant’s production facilities produce two types of heating boilers: solid fuel models and Zota electric boilers.

We are interested in the latter because a large number of Consumers today give preference to electric heating units. There are several reasons for this.

Here are excellent technical characteristics, a variety of models from economy class to luxury options that can heat rooms with an area of ​​30-4000 m2, reasonable price and ease of installation and maintenance. And as practice shows, it is all this together that makes the Zota boilers so popular.

The lineup

So, in the model line of Zota electric boilers there are five models:

Economy model

This is the cheapest model, but in terms of operational and technical specifications not inferior to any other model. This is a fully automated design with a remote control panel. Boilers can be installed in heating systems with natural and forced movement of coolant.

A distinctive feature is that the boiler and process control unit are located in different buildings. They are installed separately and connected by wires. It should be added that Zota economy class boilers with a power of 3-15 kW can operate both from power relay installations and from standard magnetic starters.

Automation heating device makes it possible to regulate temperature regime in the range from +40C to +90C. These are the optimal limits that allow you to adjust the mode to save fuel consumption. Note:

  • Economy class Zota boilers with a power of 3-15 kW are manually adjusted.
  • Units with a power of 18-45 kW are configured automatically.

All boilers of this model are equipped with a self-diagnosis system. This makes it possible to identify flaws in thermal processes and breakdowns of components and parts in advance.

Lux

The Lux model is considered the most popular and popular. It is intended for heating houses with an area of ​​30-1000 m². This is a fully automated electric unit that is improved every year, acquiring new options and functions.

All boilers of this model are equipped with block heating elements made of stainless steel tubes. The most advanced automation has been installed, allowing for good savings on fuel consumption.

MK

These are mini boiler rooms, which include:

  • Electric boiler with characteristics similar to the Zota Lux boiler.
  • Power block.
  • Control block.
  • Expansion tank of membrane type.
  • Circulation pump.
  • Security block.
  • Pipe junction with shut-off valves.

And all this in one building. What does this mean in practice?

  • Firstly, due to the compactness of the device, mini boiler rooms do not require a large installation space.
  • Secondly, this configuration allows you to save on additional materials.
  • Thirdly, it is easy to install. Here you only need to connect to the power supply network and connect the pipes to the circuits of the heating system of the house.

Advice! For ease of control and configuration of the MK, we recommend installing GSM module, which will allow you to control all heating processes using a cell phone while away from home. This option is installed on demand only.

Let us add that Zota MKs are produced with a power from 3 kW to 36 kW. For small ones country houses- This best option for heating.

Installation Rules

Like all types of electric boilers, the Zota brand is available in two variations: floor-mounted and wall-mounted, single-phase and three-phase. The installation rules for single-phase models are simple:

  • It is necessary to install the unit itself.
  • Connect it to the home heating system.
  • Plug it into a power outlet.

The only thing that needs to be done is to run a separate power cable from the distribution panel and install a separate machine. With three-phase analogues it is more difficult. If you are not an electrician, then it is best to leave the installation to professionals. It is both reliable and safe.

Operation of the boiler is quite simple. The instructions contain provisions with which you can easily adjust the device to the desired air temperature parameter. The device will do the rest itself.


A fairly wide range of Zota electric boilers allows you to select the required model exactly to meet the consumer’s requirements. Will help increase ease of use additional options. They, of course, increase the cost of the product, but the quality of work only improves. Therefore, it is worth paying attention to the options and choosing the ones that suit the operating conditions.

The domestic company ZOTA is known not only in Russia, but also abroad. It specializes in the production heating equipment And additional accessories. By installing a ZOTA electric boiler in their home or dacha, people make their choice in favor of a high-quality and reliable product from a Russian brand. In this review we will cover:

  • About the main lines of electric boilers;
  • About popular models;
  • About connecting and operating ZOTA boilers.

Lastly, you'll be introduced to user reviews.

Features of ZOTA electric boilers

When developing ZOTA electric boilers, the manufacturer does everything possible to ensure that the equipment is of high quality and modern. Therefore, today it is one of the leaders in the heating market. The boilers we produce are reliable and economical, they can be controlled remotely, and their functionality fully meets the requirements for modern technology.

To remotely control ZOTA boilers, a GSM module and a special application are used.

ZOTA company produces equipment for heating buildings for various purposes– these can be private houses, industrial premises, administrative buildings, warehouses and much more. The power of the models varies from 3 to 400 kW, which corresponds to the area of ​​heated premises from 30 to 4000 sq. m. m. For control, remote or built-in remote controls are used, as well as Cell phones, controlling boilers via GSM channels. There are five model ranges for buyers to choose from:

  • ZOTA Econom - inexpensive ZOTA electric boilers for home and buildings with an area of ​​up to 480 sq. m. The line is distinguished by its simplicity and affordable prices;
  • ZOTA Prom is a special line of especially powerful boilers designed for heating rooms from 600 to 4000 sq. m. m;
  • ZOTA Smart - electric boilers with GSM modules for remote control. They are literally crammed with all kinds of electronics;
  • ZOTA MK - mini boiler rooms with remote control. Designed to heat rooms from 30 to 360 square meters. m;
  • ZOTA Lux are small-sized boilers with many functions and advanced design. Equipped with GSM modules and temperature correction circuits.

Let's look at these lines in more detail.

Electric boilers ZOTA Econom

This line includes simple electric boilers used to heat buildings for various purposes. Low-power models are well suited for creating home heating systems. Boilers are equipped with remote control panels that provide automatic regulation temperature. Despite its simplicity, the boilers of the ZOTA Econom line contain self-diagnosis systems. To ensure reliability and long service life, the production equipped them with rotation systems for power units and heating elements.

Electric boilers ZOTA Prom

This line includes particularly powerful electric boilers designed for heating large buildings. They are also used for preparing hot water. All models in the line are designed for floor installation. To ensure efficiency, the boilers are equipped with automation systems, and a long service life is ensured using a heating element rotation system. Control is carried out using remote control panels.

Electric boilers ZOTA Smart

Compact electro boilers ZOTA They are distinguished by the presence of sophisticated electronic controls. They are equipped with automation systems, weather-compensating modules, heating and pump control systems, as well as self-diagnosis systems. All models supplied to the market have built-in GSM modules for remote control. The boilers are designed with stainless steel heating elements, numerous sensors, as well as ports for controlling three-way valves and circulation pumps.

Electric boilers ZOTA MK

These are no longer just boilers, but entire mini-boiler houses. Distinctive feature is the presence of a built-in harness - there are inside expansion tank 12 liters, circulation pump and safety group. Control is carried out using the built-in remote control; new models provide the ability to install GSM modules. The lineup It is distinguished by its small dimensions and neat execution.

Electric boilers ZOTA Lux

Electric boilers ZOTA Lux are designed for heating homes and production premises. They are equipped with smooth power control, protection systems, remote control, external equipment control systems, as well as durable heating elements. A nice addition will be the presence of weather-dependent automation and the ability to work with two-tariff meters.

If you need to provide excellent heating for a private household, then ZOTA Lux electric boilers will be the most optimal choice– they are characterized by a long service life and advanced functionality.

Popular models of ZOTA boilers

Electric boiler ZOTA 6 Econom - a good option for heating private non-gas-free houses of small area.

The leader in popularity was the electric boiler ZOTA 6 Econom. This is enough simple model oriented towards wall mounting. Management is carried out from remote control, sold separately. The boiler can operate from both single-phase and three-phase network. Distinctive features– three-stage power adjustment, electronic control, overheating protection. It is possible to work with warm floors. The boiler power is 6 kW, the maximum heating area is 60 sq. m.

The list of top models includes ZOTA Lux electric boilers - these are the ZOTA 7.5 Lux, ZOTA 9 Lux and ZOTA 12 Lux models. The power of the boilers is indicated in the numerical indices of the presented models. They are made according to a single-circuit design and are equipped electronically controlled. There are programmers, self-diagnosis systems and security systems on board. Boilers can work with heated floors and room thermostats. There is also the possibility of control via a GSM channel.

Models with a power of 7.5 and 9 kW can operate from single-phase networks. The ZOTA 12 Lux boiler operates exclusively on three-phase electrical network– this is due to high power consumption.

Our list of popular models includes the ZOTA 12 MK mini boiler room. A power of 12 kW allows you to heat houses and buildings with an area of ​​up to 120 square meters. m. The device is equipped with a programmer, a security group, circulation pump and security systems. The boiler operates from a three-phase electrical network. Models released after 2012 provide the ability to connect GSM modules.

Instructions for use

The attached instructions for the ZOTA electric boiler will allow you to quickly complete installation and carry out initial setup. Before connecting the boiler, make preparatory work. If the device’s power is more than 3 kW, a separate electrical line is laid to it. It is not necessary to install an RCD, since almost all models have it (if not, select a machine that is suitable in terms of current and voltage).

Heating circuit with electric boiler ZOTA as heating element.

When choosing a place to install a ZOTA electric boiler, you need to make sure that there is no water vapor or aggressive gases in the room, and that the air temperature is in the range from +1 to +30 degrees. Simple fluid is used as a coolant tap water or a special non-freezing liquid. The boilers are installed strictly vertically. When connecting equipment to the electrical network, it is necessary to provide grounding - it is connected to boilers and pipes.

Installation of ZOTA boilers is carried out according to the attached instructions - maintaining the distance to the ceilings, floors and adjacent walls. The device must be in such a position that there are no obstacles to its cooling (here we use natural ventilation). At the last stage, the boiler is connected to heating system. Next, a leak test and a test run are carried out.

Remember that the pressure in the heating system should not exceed the parameters specified in the passport. Otherwise, equipment damage may occur.