general description

"Technoruf N30" is a hydrophobized non-flammable sound and thermal insulation material, which is made in the form of slabs. it is based on rocks, which belong to the basalt group. The ingredients include a low phenolic binder.

Purpose of insulation

"Technoruf N30", the technical characteristics of which you should know before purchasing, is intended for arranging a thermal insulation layer in roofing systems, made of metal profiled flooring or reinforced concrete. Among other things, this material can be found as protective screeds in industrial and civil construction. It has found its wide distribution in the process of carrying out new work and reconstruction of buildings, as well as structures that can have all kinds of purposes.

"Technoruf N30", the technical characteristics of which force consumers to incline their choice in its direction, should be stored in a covered warehouse. It is permissible to leave the material under a canopy that can protect the slabs from negative impact atmospheric precipitation. During storage, it is recommended to stack canvases on pallets or in containers. The height of one stack should be 2 meters. Do not exceed the mentioned parameter.

Main physical and mechanical features

"Technoruf N30", the technical characteristics of which are of interest to many consumers today, has compressive strength at 10% deformation within 30 kPa. Experts are quite often interested in concentrated load; it is equivalent to 400 H. The material is not flammable, and its vapor permeability is 0.3 mg/(m·h·Pa). Humidity by weight upon purchase cannot exceed 0.5%. When exposed to water, water absorption by total volume cannot exceed 1.5 percent. Among the remaining ingredients, the organic content is 4.5%. The density of the material can vary from 100 to 130 kilograms per cubic meter.

Geometric parameters

If you decide to purchase Tekhnoruf N30 insulation, then it is important to inquire about its standard parameters. The manufacturer produces slabs whose length can be 1000 and 1200 millimeters. The width can be selected from two indicators, which are equal to 500 and 600 millimeters. The thickness varies in increments of 10 millimeters from 50 to 200 millimeters.

Tekhnoruf N 30 This mineral wool board, produced on high-tech equipment in accordance with high quality standards. The mineral basalt fibers included in its composition, bonded with an organic binding element, are impregnated with a water-repellent composition, which makes this material durable, wear-resistant, water-repellent, heat and sound insulating, resistant to chemical exposure, non-flammable. Thanks to the uniform bundle of fibers, the material is environmentally friendly, as it is not subject to crumbling and, therefore, the spread of dust, that is, it is safe for health.

Application area

IN modern construction insulation Tekhnoruf N 30 widely used as the first layer in multi-layer systems for insulating flat, unused roofs. These special roofing materials They cope well with the functions of insulation and sound insulation on non-loaded flat roofs, both horizontal and with a slope. Excellent heat and sound insulation characteristics, ease of installation, strength and durability, wear resistance, inflammability, and hydrophobicity have made this material practically irreplaceable not only in new construction, but also in the repair and reconstruction of buildings of the widest range. functional purpose. Widely used in both construction industrial buildings, and private houses. The durability of the material, more than 50 years, allows you to save on all subsequent alterations. A roof insulated with this material will serve well for decades without losing its properties. thermal insulation characteristics, and the environmental friendliness of the material makes it safe for human health.

Fire resistance

Minplates N 30 belong to the class of non-combustible materials with a melting point of the mineral fibers included in the composition of 1000°C and with a melting point of the organic binding element of 250°C. The temperature range at which this material can be used in construction is from -60 to 400°C. Thus, the material is universal for use in almost all climatic zones without loss of quality and high performance characteristics.

Technical characteristics of Tekhnoruf N 30

Parameter name Tekhnoruf N 30
Density, kg/m3 90-110
Compressive strength at 10% deformation, kPa, not less 30
Thermal conductivity at 10 °C, W/(m.°C) no more 0,034
Thermal conductivity at 25 °C, W/(m.°C) no more 0,036
Thermal conductivity under operating conditions A, W/(m°C) no more 0,041
Thermal conductivity under operating conditions B, W/(m°C) no more 0,044
Vapor permeability, mg/(m.h.Pa) not less 0,30
Humidity by mass, % no more 0,5
Water absorption by volume, % no more 1,5
Flammability, degree NG

The roof, as you know, is one of the main enclosing structures of a house; it must withstand not only the impact environment, but also the most extreme temperature conditions. The heat insulator, which is used to insulate roof structures, also has special requirements, especially when it comes to the roof used. And one of the materials that is perfect for such conditions is Tekhnoruf insulation, which will be discussed in today’s article.

Main advantages of the material

Tekhnoruf insulation has numerous advantages, the most important of which are given below.

  1. Opportunity effective insulation roofs.
  2. Long service life.
  3. Possibility of installation on an unleveled surface. In addition, the screed is also not a prerequisite.
  4. All installation steps can be completed by yourself.
  5. After insulation, the roof can be used as a floor, even without installing a concrete screed on top of the material.
  6. No special equipment is used in the work.
  7. There are no wet processes during installation.
  8. Finally, the duration installation work insignificant.

Note! This insulation can be laid on any surface - corrugated board, concrete, sheet steel and even cement screed. But at the same time, neither leveling the surface nor using polymer glue for fixation is required.

Prices

The specific cost of the material depends on both the modification and the region. On average, it varies between 2,535 and 5,019 rubles per cubic meter.

Types of insulating material

There are several product lines, let's get acquainted with the features of each of them.

Actually, Technoruf

This is how we decided to call the modification of the material, which can be used for insulation without any additions, that is, alone. This material is intended for use as the main thermal insulation layer for all types of roofing, regardless of what material the surface is made of. The dimensions of the products in this case are as follows (LxWxT): 100/120x50/60x5-11 centimeters. As for specific modifications, they are listed below (for the convenience of visitors, the information is presented in the form of a small table).

Table No. 1. Specifications heat insulator Tekhnoruf

Index Tekhnoruf 45 Tekhnoruf 50 Tekhnoruf 60 Tekhnoruf 70
Density kg/m3 140 160 170 180
45 50 60 70
Peel strength of layers kPa no less 10 10 10 10
0,037 0,037 0,037 0,037
0,039 0,039 0,039 0,040
0,043 0,043 0,043 0,044
0,046 0,046 0,046 0,047
Vapor permeability 0,3 0,3 0,31 0,32
0,5 0,5 0,5 0,5
1,5 1,5 1,5 1,5
4,5 4,5 4,5 4,5
Flammability degree NG NG NG NG

It is worth noting that all these products have been on sale since 2007.

Technoruf N

Such modifications are also suitable for any surface, but are intended for installation in combination with the insulation described below (we are talking about modifications B). They have excellent noise, thermal and moisture insulation properties, but, being not strong enough, they need to be “protected” more durable material. Dimensions of material slabs (LxWxT): 100/120x50/60x5-11 centimeters. The main parameters are given below.

Table No. 2. Technical characteristics of the Tekhnoruf N heat insulator

Index Tekhnoruf 25 Technoruf H30 Tekhnoruf 35 Tekhnoruf 40
Density kg/m3 95 100 110 120
Compressive density at 10% strain 25 30 35 40
Thermal conductivity at 10 C no more 0,036 0,036 0,036 0,036
Thermal conductivity at 25 C no more 0,039 0,039 0,039 0,040
Thermal conductivity under operating conditions A 0,042 0,042 0,042 0,042
Thermal conductivity under operating conditions B 0,045 0,045 0,045 0,045
Vapor permeability 0,29 0,3 0,3 0,31
Humidity by mass% no more than 0,5 0,5 0,5 0,5
Water absorption by volume % no more 1,5 1,5 1,5 1,5
Content of organic substances % no more 4,5 4,5 4,5 4,5
Flammability degree NG NG NG NG

Tekhnoruf V

Tekhnoruf insulation is similar in its properties, which, however, has higher strength. For this reason, it should be used as the top layer of a thermal insulation cake. Let's get acquainted with the main parameters.

Table No. 3. Technical characteristics of Tekhnoruf V

Index Technoruf B 50 Tekhnoruf B 60 Tekhnoruf B 70
Density kg/m3 170 180 190
Compressive density at 10% strain 50 60 70
Thermal conductivity at 10 C no more 0,037 0,037 0,037
Thermal conductivity at 25 C no more 0,040 0,040 0,040
Thermal conductivity under operating conditions A 0,043 0,043 0,045
Thermal conductivity under operating conditions B 0,046 0,046 0,046
Vapor permeability 0,30 0,31 0,35
Humidity by mass% no more than 0,5 0,5 0,5
Water absorption by volume % no more 1,5 1,5 1,5
Content of organic substances % no more 4,5 4,5 4,5
Flammability degree NG NG NG

As a rule, of all the described modifications, these are the most often used - H30 and B60. Installing double insulation generally allows you to achieve maximum effect. For convenience, each layer is labeled separately.

Modification H30

Intended (and actively used) for roof insulation and sound insulation. The vapor permeability of the material is quite low, as is the compressive strength (this means that it is installed in tandem with denser modifications). In general, the material is quite effective and durable.

Regarding specific technical information, then it is given below.

  1. The insulation is not flammable.
  2. Its thermal conductivity can reach 0.045 watts/cubic meter.
  3. The strength indicator is 30 kilopascals.
  4. The density of the heat insulator is 100 kilograms/cubic meter.

Modification B60

Another type of material that is very popular. It is used as a top layer, as it is characterized by increased compressive strength. This ensures the required rigidity of the entire coating.

As noted above, this material can be used both for metal surfaces, and for reinforced concrete, and it does not require any preliminary screeding. And there is no need to cover it with a screed either, thanks to which the surface is able to withstand the most significant point loads. Thanks to the use of insulation as thermal insulation of roofs, a durable surface is provided, characterized by waterproofness and wear resistance, as well as the ability to preserve most thermal energy.

As for the specific parameters, they look approximately as follows.

  1. The insulation is not flammable.
  2. Its thermal conductivity can reach 0.046 watts/cubic meter.
  3. Its moisture absorption is 1.5 percent.
  4. The strength indicator is 60 kilopascals.
  5. The concentration of organic matter is 4.5 percent of the total mass.
  6. The density of the heat insulator is 180 kilograms/cubic meter.
  7. Finally, the moisture level does not exceed 0.5 percent of the total mass.

Installation Features

Let’s immediately say that installing the heat insulator described in the article is a fairly simple procedure. First, the working surface is thoroughly cleaned of all foreign objects present on it. After this, it is laid over the entire area vapor barrier layer(both a polymer membrane and bituminous materials). Joints between stripes insulating material glued using mounting tape.

Note! The insulation boards themselves should be laid in a checkerboard pattern (that is, so that the joints of adjacent rows do not coincide). To fasten the material, special telescopic dowels should be used (approximately two to three units for each of the insulator plates).

For a more detailed overview of the installation process, we recommend that you read the following step by step instructions. As you can see, it is quite short, which is another proof of the ease and simplicity of the process. The algorithm of actions should be as follows.

Step one. Working surface thoroughly cleaned of all foreign objects on it, as well as dirt and debris.

Step two. It is laid around the entire perimeter vapor barrier material(as such, as noted above, both polymer membranes and bitumen-based insulators can be used). The joints between the strips are glued using mounting tape, and the strips themselves are laid with an overlap. It is also worth noting that the vapor barrier should be installed on the sides of the roof to the height of the entire thickness of the insulating pie plus 20 millimeters.

Step three. Plates of insulating material (modification H, although in most cases H30 is used, as far as we already know) are laid on top of the vapor barrier. Laying is done in a checkerboard pattern - the same way, for example, bricks are laid (the joints of adjacent rows should not coincide). To fasten the insulation, special telescopic dowels are used (two units for each of the plates, although you can increase the strength and use three or even four).

Step four. Modification B slabs are installed on top of the lower insulating layer (they are intended for the top layer of the cake); in this case, telescopic dowels made of nylon are used for fixation. The joints in this case are also tied (in other words, the joints of the lower row should be located approximately in the center of the slabs of the upper row - they seem to overlap). The specific type of dowel anchor elements should be selected according to what is in each specific case floor material.

Step five. Placed on top of the insulation waterproofing material (best option– polyvinyl chloride membrane).

Note! Places of contact with sides or pipes, as well as various slopes, are organized using special additional/shaped components, which were also provided by the manufacturer. These components are also made from basalt wool, thanks to which they can be used in arranging roofs of various shapes.

As you can see, no specific skills or knowledge are required here. The only thing that may be difficult is the installation of a PVC membrane, since this will require experience in working with similar materials, as well as welding work.

Video - Installation of Tehnoruf insulation

Nuances of flat roof insulation

Flat roofs are insulated using external insulation, in other words, the one located above the ceiling. Rolled waterproofing material is usually laid on top of the insulation, bitumen mastic or polyvinyl chloride membranes.

If the roof in use is insulated, then, as noted above, special requirements are put forward for the heat insulator, namely increased compressive strength. When using mineral wool, this can be achieved solely through compaction and increasing the concentration of the binder. Because of this, not only does the cost of the material increase, but also the thermal insulation properties deteriorate (thermal conductivity increases).

In order to prevent this problem, a reasonable decision was made: to use a two-layer structure of insulating material, in which there will be a softer layer with increased heat resistance on the bottom, and a layer with increased density and rigidity on top. Thanks to this, the total cost of insulation has noticeably decreased, while the efficiency, on the contrary, has increased.

It is also worth noting that modern manufacturers They produce special wedge-shaped slabs, with the help of which you can create a slope of the roof in order to more effectively drain water into the appropriate openings.

Note! Application double thermal insulation roofing makes it possible to do without a screed (both before and after laying the insulation) even in cases where it – the roof – is in use. But if the loads are still significant, then a screed can be installed if desired.

Features and properties of insulation

Teploruf mineral wool slabs (and the most popular of them are those marked H30 and B60) have gained enormous popularity in the construction of a wide variety of objects. The material has excellent thermal conductivity, and its use for insulation practically does not increase the thickness of the roof or wall section.

The weight of mineral wool is insignificant, therefore, its installation does not cause any difficulties and is done quite quickly. Thanks to all these performance qualities, the Tekhnoruf heat insulator allows you to insulate any type of roof with extreme efficiency.

The B60 modification, which is the latest in the insulation pie, deserves special attention. This is clear evidence that the thermal conductivity of the material, as well as its strength, is sufficiently high level. This insulator meets all modern standards quality and is used as a top layer for insulation flat roofs, due to which the required structural rigidity is achieved.

It is also worth noting that the described material is used to insulate those surfaces that are made of reinforced concrete or iron sheets. At the same time, the surface itself acquires the ability to withstand significant mechanical loads.

Video – Thermal insulation Technoruf

Areas of application and purpose of heat insulator

Objects for both industrial and residential purposes always require additional thermal insulation. And with the help of Tekhnoruf slabs, it is possible to form the main insulating layer on surfaces made of both reinforced concrete and metal. Moreover, these products can be used as a heat-saving element on roofs that are sloping. And thanks to their versatility, they can be installed even on unused roofs (for example, in industrial buildings).

Note! Due to their high strength properties, the slabs are also actively used for roof insulation, which are used quite often.

If you wish, you can even insulate walls, facades and ceilings using Technoruf. High compressive strength allows you to install a cement screed (even reinforced) on top of the heat insulator. All modifications of the material described above belong to the class of thermal insulating building materials increased strength. This kind of mineral wool is widely used when carrying out repair work, as well as during the implementation of large-scale construction projects.

Finally, the material can also be used to insulate small private houses, since it has such qualities as ease of installation, increased thermal insulation properties and resistance to various types of chemical influences.

Internal structure of insulation

The Tekhnoruf insulation described in the article does not burn; it is produced in the form of thermal and sound insulating boards with increased hydrophobicity, made using mineral wool. Myself manufacturing process is based on the use of the latest technological developments.

The material is almost 100 percent composed of small fibers of the mineral basalt. The fibers are connected to each other using a special organic matter. At the appropriate stage of manufacturing, each slab is treated with a special moisture-repellent impregnation, which is why, in fact, the material acquires the hydrophobicity mentioned above. This point, by the way, is especially important, since during installation work it is not always possible to prevent water from getting on the products.

The fibers are arranged horizontally/vertically; thanks to this structure, the slabs can withstand significant point loads, moreover, they redistribute them (the loads) qualitatively. The fibers are placed in this special way thanks to the use of a corrugator-presser.

The last stage of production consists of packaging the products in separate packs in accordance with the specifications (a heat-shrinkable polyethylene casing is used). Note that the manufacturer guarantees a fairly long service life, but on the condition that all operating requirements are strictly observed. What is characteristic is that this moment does not depend on climate conditions and temperature changes.

Product Description:

Plates from stone wool for thermal insulation of flat roofs, TECHNORUF N is non-flammable, hydrophobized heat and sound insulating slabs made of mineral wool based on basalt group rocks.

Application area:

In civil and industrial construction as a thermal insulation layer during new construction and reconstruction of buildings and structures for various purposes.

TECHNORUF N slabs are intended for use as the bottom layer in a two-layer thermal insulation scheme in reinforced concrete or metal profiled flooring. The slabs are recommended to be used in combination with TECHNORUF V slabs.

Manufacturing jobs:

According to the “Guidelines for the design and installation of single-layer roofs from polymer membranes TechnoNIKOL Corporation, 3rd edition 2010" and “Guidelines for the design and installation of roofs from bitumen-polymer materials Roofing Company TechnoNIKOL".

Storage:

The slabs must be stored packed and stacked on pallets separately by brand and size. During the entire storage period, the material must be protected from exposure to precipitation. The height of the stack of slabs during storage should not exceed 3 m.

Transportation:

Transportation and storage of slabs is carried out in accordance with the requirements of GOST 25880-83. The slabs are shipped to the consumer no earlier than they have been kept in the warehouse for 24 hours.

Packaging Details:

Polyethylene shrink film is used for packaging. The method of wrapping and fixing the packaging material should ensure reliable and durable packaging of the slabs, their safety during loading and unloading operations, transportation and storage.

Insulation TechnoNIKOL Technoruf N30 - non-flammable material from thin basalt fibers and a binder. The thickness of one slab is 110 mm. The Tekhnoruf N30 insulation is treated with a water-repellent composition and is able to withstand short-term exposure to precipitation without loss of characteristics.

Mineral wool insulation Tekhnoruf N30 is used as the bottom layer when constructing a multi-layer thermal insulation system flat roofs with a base made of metal corrugated sheets or reinforced concrete structures. Heat melting mineral wool material allows the use of slabs in temperature range from -60°C to +250°C.

To create the top layer of insulation, you should use boards with higher compressive strength, for example, Tekhnoruf B60 with a height of 40 mm. A two-layer insulation system is beneficial from an economic and practical point of view.

Advantages:

  • non-flammable;
  • has soundproofing properties;
  • hydrophobized;
  • long service life subject to the rules of installation and maintenance of structures.

Packaging and storage

Mineral wool Tekhnoruf slabs H30 are packed in shrink film in the amount of 3 pieces measuring 1200x600x110 mm. The insulation should be stored in a dry room on pallets or pads, preventing moisture from getting on the slabs. It is possible to store Tekhnoruf N30 for short-term on open construction sites without loss of technical characteristics under a canopy/awning at a distance from the ground, protecting it from exposure to precipitation.