home · Installation · Roof ventilation vilpe. Ventilation outlets to the roof. Options for installing roof penetrations

Roof ventilation vilpe. Ventilation outlets to the roof. Options for installing roof penetrations

Vilpe roof ventilation systems are made from impact-resistant plastic and are resistant to aggressive climatic influences and corrosion. Ventilation outlets Vilpe Vent serves for reliable roof ventilation. One of the important advantages of Vilpe fans is their long service life and ease of installation.

Features of roof ventilation Vilpe

Patented Vilpe Vent roof penetrations are distinguished by their wide color scheme, modern design and variety of designs. In addition, all elements are manufactured in such a way that they can be easily combined with each other.

Vilpe roof ventilation outlets strictly comply with the standards for permissible noise levels in residential premises. Therefore, during the production of elements, special attention is paid to the noiselessness of the entire ventilation system. Vilpe fans are equipped with a noise absorber, which eliminates the transmission of motor vibration to ventilation duct.

Vilpe products have been tested and certified by independent testing centers in Europe. The products meet all fire and sanitary safety requirements in Russia.

Fans and ventilation outlets for roofing

Roof ventilation Vilpe - important element any construction. Therefore, ensuring its high quality is a matter special attention, which is fully supported by Vilpe ventilation systems - innovative products of SK Toute, a world leader in the field of ventilation equipment for roofs.

Roof ventilation systems have gained recognition due to their high levels of resistance to climatic influences and impact resistance. The products have been independently tested in leading testing centers in Europe. Vilpe fans comply with all permissible noise standards in residential premises, as well as basic sanitary and fire safety requirements.

The advantage of Vilpe ventilation outlets is their ease of installation and the ideal combination of all system elements. The quality of the ventilation system is also ensured by the excellent design of all its parts.

With the help of Vilpe series fans, it is possible to carry out penetrations for any type of roof, with any level of its slope. The manufacturer's warranty provides 10 years of proper operation of the system, but in practice the service life turns out to be longer.

Vilpe product catalog





Elements of the Vilpe ventilation outlet system

Vilpe roof ventilation systems include silent fans interior spaces, ventilation outlets for kitchen hoods and sewer risers, antenna outlets, roof ventilation elements, roof hatches, as well as sealed passage elements for various types roofs.

Pass-through element MUOTOKATE Vilpe Vent

The passage element for metal tiles is installed on finished roof with Monterrey profile. For ventilation outlets of different diameters 110,125,160. Big choice colors for any metal tile.

PELTI Vilpe Vent passage element

The UNIVERSAL passage element for metal tiles is mounted on different types of tiles with a profile height of up to 38 mm. The tightness of the installation is ensured by a rubber seal with aluminum, which takes any shape.

NERA 2K Vilpe Vent passage element

Pass-through element for metal tiles Ruukki mounted only on Finnera profile and Grand Line Kvinta. For ventilation outlets that are installed on roof penetration creating ventilation of living spaces.

Passage element CLASSIC Vilpe Vent

Classic roof penetration for seam and finished pitched roofs bitumen roofing. Installed on a finished roof. The tightness of the installation is ensured by a rubber seal on the inside penetrations.

Pass-through element UNITILE 2K Vilpe Vent

The passage element is UNIVERSAL for all types of cement-sand and ceramic roofing. Mounted on 1-, 2-wave and smooth tiles; installation of this element is possible during installation on finished tiles.

Passage elements through the roof, types and price

A smartly constructed building is thought out to the smallest detail engineering systems. Many of them, for example ventilation, require output to the roof surface. To ensure that communications are in contact with the roof as tightly as possible, passage elements are used. Roof penetration for different types roofs will do as for metal profiles, as well as any other roofing coverings. Universal passage elements can take any shape, so the pattern of the wave or the level of inclination of the slope does not matter. You will receive excellent sealing regardless of the type of roof.

The main material for the production of roof penetrations is special rubber or high quality silicone. It is resistant to any temperature and will not change its properties in the event of a sudden change in weather. Thanks to the wide range of colors, you can always choose the penetration to match the style of the roof. A large selection of sizes and diameters of passage elements allows for sealing of any system of ventilation outlets. It’s easy to install roof penetrations yourself; no special skills are required. All you need is a minimum of tools and the correct size. Sealing with penetration will protect your roof from precipitation and significantly extend the service life of roofing materials.

Basic colors of pass-through elements:

Black
RAL 9005
Terracotta
RAL 8004
Green
RAL 6020
Brown
RAL 8017
Red
RAL 3009
Grey
RAL 7024

Video instructions for installing pass-through elements

Muotokate Pelti
Classic Tiili

The roof ventilation outlet is the final element of the ventilation or aerator system through which the pipe exits. The products ensure the tightness of the junction of communications with the roof, and also provide an aesthetic appearance node. So-called fungi protect the ventilation system from precipitation and wind blowing.

The need to pass ventilation pipes through the roof is due to the fact that this method allows creating natural draft in the system. The location of the outlet at a height will ensure the creation of a comfortable atmosphere in the room and will speed up the removal of waterlogged and polluted air from the kitchen, bathroom or workshop.

The most important advantage of roof hoods for exhaust hoods is that they eliminate the need to create a bulky brick riser. The sealed outlet allows pipes to be laid in any in a convenient way. The use of such a design is much cheaper, its installation requires less time and money, ready-made solution does not spoil the appearance of the roof and does not require any maintenance.


Assortment of ventilation outlets for corrugated sheets, seams, metal tiles, soft roofing

The design of the fungus includes not only visible part, but also a system of passage and sealing elements, as well as pipes (for certain models). For some products you can select an adapter for use as a . Generally design features of such elements depend on the type of coating on which installation will be performed.

Our catalog presents outputs of various foreign and domestic brands, including:

  • Finnish Premium products that have earned the trust of professionals. The manufacturer offers many solutions for the most different roofs;
  • . Budget series, which is made of reliable rubber and silicone. The catalog contains penetrations for cables with a thickness of 6 mm and pipes with a diameter of up to 100 cm. Important distinctive feature products - heat resistance;
  • . They are produced under the Russian brand in Denmark and are an advantageous combination of reliability and affordability. The elements are supplied assembled. The catalog contains penetrations for corrugated sheets;
  • . The outputs of the Russian brand are made from materials that are resistant to fading. The range includes many models for common types of roofing.

To buy an outlet for a ventilation pipe on the roof, place an order on our website or provide order information by phone.

and the whole house. Correctly selected and installed ventilation elements for residential and non-residential premises, plumbing units and under-roof space - a guarantee of comfort, a healthy atmosphere and the durability of your home.

In this article we will describe in detail which ventilation elements are presented in our range, in what cases they are used and what problems they solve.

Roofing structures always contain moisture: insulation and truss structure absorb it during the construction of a house; condensation forms on the bottom surface roofing material; while living in the house, moisture evaporates in the form of water vapor and enters the insulation and wooden structures; In case of heavy rain or snow and oblique winds, a small amount of water may get under the roofing material.

Precisely for removing moisture and ventilation roofing system install ventilation elements. Their absence or ineffective work leads to the following consequences:

· accumulation of moisture, formation of condensation on rafters and substructures, and subsequently mold and mildew, destroying wooden elements;

· corrosion metal structures, destruction of brick and concrete parts;

· formation of ice on the roofing material and, as a result, damage to the roof and drainage system, penetration of melt water under the roofing during thaws;

· moistening of thermal insulation, leading to a sharp decrease in its efficiency and an increase in the cost of heating the house;

· overheating of roofing material in summer (this especially has a detrimental effect on bitumen coatings) and the interior of the attic;

· increased costs for air conditioning of internal premises.

Ventilation elements for the under-roof space connect the under-roof space with the outside air. The operating principle of under-roof ventilation is based on the use of differential pressure and air flow. For effective ventilation, an air flow is necessary at the lowest point of the roof, that is, at the eaves of the roof, and roofing fans provide the outlet of this air to the upper points, for example, at the ridge or at the junction of the slopes with the walls, and effectively remove moisture.

Constant ventilation of the insulated roof structure is a necessary condition long-term and reliable service of the entire building. The importance of ventilation can hardly be overestimated - thanks to air flows, it is removed from the structure excess moisture, eliminates the likelihood of mold and fungi, destruction wooden elements roofing and insulation.

The choice of roofing fan depends on the type of roofing material; they can be installed on both roof slope, and finally. In addition to ventilation of the under-roof space, roof fans are used for ventilation of attic spaces. Required amount valves depends on the roof structure.


Maintaining tightness is an important task that needs to be solved when installing natural or forced ventilation and other elements.

Pass-through elements ensure a sealed passage through the roof, vertical installation of pipes on the slope and the operability of the internal ventilation system, sewer risers, antennas and other elements. Passage elements are selected according to the diameter of the element leading to the roof and are mounted on almost any roof. Installation is quick and simple, without the use of sealing tapes, the service life of which is significantly less than the service life of the roofing material, which subsequently leads to leaks.

For hermetically sealing cables and pipes of small diameters to the roof, for example, inlet and outlet pipes solar battery, you can use SOLAR pass-through elements.


During the first years after construction, there is an active release of particles from building materials that accumulate in the air. Human activity and pets also degrade air quality. Contaminated and not removed from premises wet air penetrates into structures, causing the growth of fungi and mold, affecting human well-being.

To prevent this from happening, the house must “breathe”, creating favorable conditions for the people living in it. In accordance with sanitary standards, the air in the house must be completely replaced every two hours. This is achievable only with the help of correctly calculated and executed ventilation of the premises. The house must have an influx fresh air, which is organized only in living and sleeping rooms. These rooms are not ventilated. Ventilation allows you to direct air currents in the house so that the air from living and sleeping rooms flows into rooms with polluted and damp air and from there it was brought out. With this organization, the air in the toilet, kitchen, bathroom, pantries will not spread into living rooms. To do this, exhaust valves are installed in the ceiling or walls of rooms with damp and dirty air and, using air ducts, are brought to the roof where they are installed. ventilation pipes with pass-through elements.

The kitchen hood from the stove is ducted to the roof separately. It is not recommended to discharge it into a common air duct, since grease pollutes the air ducts and unpleasant odors can spread throughout the living quarters.

Ventilation of premises with gas equipment required according to current construction requirements SP 42-101-2003. The air from the boiler room is discharged onto the roof separately using ventilation pipes with internal diameter 160 mm.

To avoid the appearance unpleasant odors, destruction sewer system due to gases formed in the sewer, and normal operation water seal, sewer risers must have a ventilation outlet to the roof. It equalizes the pressure in the system at the time of draining and removes gases that destroy the pipes.


For sewer risers, it is recommended to use ventilation pipes with an internal diameter of 110 mm, which can be thermally insulated or non-insulated. Uninsulated pipes are recommended for ventilation of sewer risers in regions with mild climates. Thermally insulated ventilation pipes are recommended for ventilation of sewer risers in regions with long frosty periods. IN insulated pipe no ice plug is formed that interferes with the ventilation of the riser. The ventilation pipe is connected to the sewer riser using a corrugated pipe with a diameter of 110 mm.

Forced ventilation performs the same functions as ventilation pipes, but is much more efficient.

Proper ventilation of the house involves creating a reduced pressure in the house in relation to environment. In this case, the walls and ceilings receive fresh air, and the structures are ventilated and dried - fungus and mold do not grow in the walls.

Reduced pressure in the house is effectively achieved by forced ventilation.

Rubber seals and pipe gates provide a sealed exit to the roof for antenna rods, pipes, cables, etc.

Seals Available in several sizes to suit various diameters pipes, there are one-piece and detachable. The latter are used to seal the junctions of finished objects that cannot be sealed with permanent seals. A flexible EPDM rubber seal allows thermal and mechanical vibrations, sealing the hole in the roof.


EPDM rubber is resistant to weather conditions and ultraviolet radiation, and tolerates the effects of acids and alkalis contained in the air of industrial areas. Seals are installed directly on the roofing.

Gate consist of an EPDM rubber seal in the upper part of the element and a plastic gate in the lower part, which is installed on standard passage elements, selected depending on the type of roofing material.


PIIPPU pass-through elements are designed for hermetically sealed output of round metal heat-insulated panels onto the roof. chimneys. The product is available with a diameter of 200-265 mm or 280-380 mm, and can be installed on roofs made of metal, flexible and natural tiles, also suitable for standing seam roofing.

The PIIPPU passage element has passed fire tests in the VTT laboratory of Finland and has fire certificates.



7. Roof deflectors

Roof deflectors have the same purpose as roof fans - ventilation of the under-roof space and attic space. The installation of roof deflectors is recommended on roofs with low pitches or in regions with large amounts of snowfall, that is, in cases where the correct functioning of roof fans is impossible. Deflectors are installed on roofs made of bituminous materials on the ridge of the roof or on the slope.


Moisture always accumulates in the basement of buildings, causing harm. building structures. The most effective air circulation in the basement of the building is achieved by simultaneously using forced roof ventilation for exhaust and a basement deflector as a supply pipe. Forced fan connects to plastic pipe, which leads to the basement.

Ventilation of the base can also be carried out in the system natural ventilation, installing an insulated ventilation pipe on the roof instead of a forced fan.

It is possible to ventilate the basement space using only basement deflectors.


For proper operation ventilation systems in the house must ensure air flow into the premises. For this purpose, ventilation grilles or supply valves are used.


Supply valves provide filtration and supply of fresh air into the premises. The valve is equipped with a thermostat that is sensitive to temperature fluctuations. The air flow changes automatically depending on changes in outside air temperature. The thermostat setting can be changed as needed. The valve has a filter that traps dust, pollen and the most hazardous mineral microparticles.

The roof hatch is a technical and fire hatch, used for access to the under-roof space or attic.


If you have any questions about the range of ventilation elements, their purchase or installation, contact us in any convenient way or come to our customer service centers.

Roof ventilation from SK Tuote Oy is a standard of engineering and an example of the quality of all products. By purchasing roofing outlets from this brand, you can be sure of highest quality and durability of all Vilpe products. All Vilpe products Vent is made from impact-resistant polypropylene that is non-corrosive, UV and weather resistant. The material is chemically neutral, can withstand constant temperatures - 40 to + 80 C, and short-term temperatures - 55 C to + 120 C.
The product line from Vilpe Vent will help to establish proper ventilation in the kitchen and bathroom. unit, basement and ventilation of the under-roof space. Proper ventilation very important for every home, it is protection against fungus, mold, excess humidity and dampness, and fresh air and a ventilated room is the key to our health and the health of our children, and, as you know, they don’t skimp on this.
All Vilpe products can be divided according to their intended purpose:
1. Ventilation outlets for sewer risers.
The ventilation outlet of the sewer riser can be insulated (insulated) or non-insulated (not insulated). Insulated outlets are recommended for regions with long frosty winters; an insulated pipe prevents condensation from freezing in the pipe; uninsulated outlets for areas with frost-free mild winters. Vent. the exit is equipped with a passage element similar to the type of roofing and a corrugated pipe if necessary.
2. Exits for hoods and ventilation.
This group roof outlets helps proper air circulation in residential and non-residential premises, and is also used to bring kitchen hood pipes to the roof. All vent. the outputs of this series are insulated, and inner tube Made from durable galvanized iron.
3. Under-roof ventilation.
It is a well-known fact that warm indoor air tends upward under the roof, carrying with it a certain percentage of moisture, which tends to accumulate under the airtight roofing covering and if there are no roof ventilation outlets, then the accumulated condensate, not finding a way out, will create an excellent moist environment under the roof for the growth of mold and fungi, thereby contributing to premature destruction rafter system Houses. This fact cannot be ignored; the solution to the problem is the installation of a cornice overhang with soffits and the installation of roof ventilation outlets.
4. Forced ventilation of the premises.
Modern houses are built from airtight materials, and the flow of fresh air is vital for both the house and the people living in it, so Vilpe roof fans perfect solution this question. They will help kitchen hood, will effectively remove condensation from the bathroom; roof fans can also be used to ventilate basements, dry closets, cafes and various outbuildings.
5. Antenna outputs and universal rubber seals.

This type of checkpoint roofing elements allows you to display on the roof: an antenna, a flagpole, an advertising structure with a diameter of up to 250 mm, while the structure is allowed to oscillate without violating its tightness, and various bases for antenna passages allow you to install a passage element on any type of roof.